Initial experience with a microprocessor controlled current based defibrillator.

نویسندگان

  • G W Dalzell
  • S R Cunningham
  • J Anderson
  • A A Adgey
چکیده

Intramyocardial current flow is a critical factor in successful ventricular defibrillation. The main determinants of intramyocardial current flow during transthoracic countershock are the selected energy and the transthoracic impedance of the patient. To optimise the success of the first shock and to titrate energy dosage according to each patient's transthoracic impedance, a microprocessor controlled current based defibrillator was developed. It was compared with a conventional energy based protocol of 200 J (delivered energy), 200 J, then 360 J if required in 42 consecutive episodes of ventricular fibrillation in 33 men and seven women. The mean (SD) predicted transthoracic impedance was 69.9 (14.0) omega. First shock success with the standard protocol was 80.9%, and first or second shock success was 95.2%. The microprocessor controlled current based defibrillator automatically measured transthoracic impedance and calculated the energy required to develop a selected current in each patient. A current protocol of 30 A, 30 A, then 40 A, if required, was used in 29 men and 12 women with 41 episodes of ventricular fibrillation. Transthoracic impedance (mean 65.1 (15.9) omega) was similar to that in the energy protocol group and success rates for first shock (82.9%) and first or second shocks (97.5%) were also similar. The mean delivered energy per shock with the current based defibrillator for first or second shock success was significantly less (144.8 J) with the energy protocol (200 J). The mean peak current of successful shocks was also significantly reduced (29.0 v 31.9 A). A current based defibrillator titrates energy according to transthoracic impedance; it has a success rate comparable to conventional defibrillators but it delivers significantly less energy and current per shock.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Microprocessor-Based Hybrid Duplex Fault-Tolerant System

Reliability is one of the fundamental considerations in the design of industrial control equipment. The microprocessor-based Hybrid Duplex fault-tolerant System (HDS) proposed in this paper has high reliability to meet this demand although its hardware structure is simple. The hardware configuration of HDS and the fault tolerance of this system are described. The switching control strategies in...

متن کامل

Appropriate evaluation and treatment of heart failure patients after implantable cardioverter-defibrillator discharge: time to go beyond the initial shock.

Multiple clinical trials support the use of implantable cardioverter-defibrillators (ICDs) for prevention of sudden cardiac death in patients with heart failure (HF). Unfortunately, several complicating issues have arisen from the universal use of ICDs in HF patients. An estimated 20% to 35% of HF patients who receive an ICD for primary prevention will experience an appropriate shock within 1 t...

متن کامل

زندگی با دفیبریلاتور قابل کاشت: یک مطالعه پدیده‌شناسی

  Background & Aim: Implantable Cardioverter Defibrillator is the most effective treatment for cardiac dysrhythmias. Having such life-saving device is the unique experience with important changes in the patient’ life. Understanding of these experiences can lead to success in treatment and follow- up.This study aimed to understand the experiences of patients with Implantable Cardioverter Defibri...

متن کامل

Defibrillator implantation for the primary prevention of sudden death in patients awaiting cardiac transplantation: one center's experience.

Patients who are on a waiting list for cardiac transplantation often have a clinical profile that satisfies current recommendations for the implantation of an implantable cardioverter-defibrillator for the primary prevention of sudden death. The prospect that transplantation may take place within the short-to-medium term puts the effectiveness of this therapy in doubt. We investigated the incid...

متن کامل

Efficacy of an implanted automatic defibrillator which had induced atrial fibrillation.

A 54 year old man with refractory life threatening ventricular tachycardia was given an automatic defibrillator. The initial system was a transvenous defibrillator coil electrode and this was later modified by implantation of two patch electrodes at thoracotomy. The modified system successfully controlled ventricular tachycardia. On one occasion reversion of ventricular tachycardia by the defib...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • British heart journal

دوره 61 6  شماره 

صفحات  -

تاریخ انتشار 1989