Real-time three-dimensional speckle tracking echocardiography: a novel technique to quantify global left ventricular mechanical dyssynchrony.

نویسندگان

  • Christophe Thebault
  • Erwan Donal
  • Anne Bernard
  • Olivier Moreau
  • Frederic Schnell
  • Philippe Mabo
  • Christophe Leclercq
چکیده

AIMS left ventricular (LV) mechanical dyssynchrony (LVMD) has emerged as a therapeutic target using cardiac resynchronization therapy (CRT) in chronic heart failure patients. Current methods used to evaluate LVMD are technically challenging and do not assess all the components of LVMD simultaneously. We analysed real-time 3D speckle tracking (3DST) echocardiography as a novel method to assess LVMD. METHODS AND RESULTS three-dimensional ST was performed in 60 unselected patients (71 ± 9 years old; 39% with ischaemic cardiomyopathy) who were referred to optimize and to control of a CRT device; implanted according to current guidelines (9 added to be excluded from the protocol). Two standardized conditions [right ventricular (RV) versus an optimized biventricular (BiV) pacing modality] were tested. These two pacing modalities lead to two distinct electrical activation patterns. We sought to test the capability of 3DST to distinguish these two patterns. The LV ejection fraction was 24 ± 9 in the RV mode and 29 ± 10% in BiV. By 3DST, we measured global end-systolic LV deformation and dyssynchrony (standard deviation of the time to peak/16 LV-segment). The 3D radial strain increased from 13.8 ± 5.7 in the RV to 15.9 ± 6.5% in theBiV mode, and the dyssynchrony index decreased from 15.1 ± 5.0 to 11.8 ± 4.1%. 3D longitudinal strain increased from -6.9 ± 2.8 in the RV to -7.8 ± 3.2% in the BiV mode, and the dyssynchrony index decreased from 14.2 ± 4.8 to 11.5 ± 5.0% (P < 0.01 for all). The 3D area strain (AS) increased from -15.4 ± 6 in the RV to -18.3 ± 7.0% in the BiV mode, and the dyssynchrony index decreased from 12.2 ± 5.1 to 9.5 ± 4.5% (P < 0.001 for all). CONCLUSION When image quality is optimal, 3DST might offer a new rapid method to quantify global LVMD in CRT candidates. In a comparison of the utility of various 3D strain measurements, the 3D AS appears to be closed to the ideal parameter that we are looking for.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Strain dyssynchrony index determined by three-dimensional speckle area tracking can predict response to cardiac resynchronization therapy

BACKGROUND We have previously reported strain dyssynchrony index assessed by two-dimensional speckle tracking strain, and a marker of both dyssynchrony and residual myocardial contractility, can predict response to cardiac resynchronization therapy (CRT). A newly developed three-dimensional (3-D) speckle tracking system can quantify endocardial area change ratio (area strain), which coupled wit...

متن کامل

Primary cardiac lymphoma causing coronary vasospasm.

left ventricular contraction pattern during right ventricular pacing: assessment using real-time three-dimensional echocardiography. ventricular ejection fraction and left ventricular dyssynchrony by 3D echo correlate with functional impairment in patients with dilated cardiomyopathy.chrony index determined by three-dimensional speckle area tracking can predict response to cardiac resynchroniza...

متن کامل

Three-dimensional mapping of mechanical activation patterns, contractile dyssynchrony and dyscoordination by two-dimensional strain echocardiography: Rationale and design of a novel software toolbox

BACKGROUND Dyssynchrony of myocardial deformation is usually described in terms of variability only (e.g. standard deviations SD's). A description in terms of the spatio-temporal distribution pattern (vector-analysis) of dyssynchrony or by indices estimating its impact by expressing dyscoordination of shortening in relation to the global ventricular shortening may be preferential. Strain echoca...

متن کامل

Real-time three-dimensional echocardiography: a novel technique to quantify global left ventricular mechanical dyssynchrony.

BACKGROUND Left ventricular (LV) mechanical dyssynchrony (LVMD) has emerged as a therapeutic target using cardiac resynchronization therapy (CRT) in selected patients with chronic heart failure. Current methods used to evaluate LVMD are technically difficult and do not assess LVMD of the whole LV simultaneously. We developed and validated real-time 3D echocardiography (RT3DE) as a novel method ...

متن کامل

Novel speckle-tracking radial strain from routine black-and-white echocardiographic images to quantify dyssynchrony and predict response to cardiac resynchronization therapy.

BACKGROUND Mechanical dyssynchrony is a potential means to predict response to cardiac resynchronization therapy (CRT). We hypothesized that novel echocardiographic image speckle tracking can quantify dyssynchrony and predict response to CRT. METHODS AND RESULTS Seventy-four subjects were studied: 64 heart failure patients undergoing CRT (aged 64+/-12 years, ejection fraction 26+/-6%, QRS dur...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of echocardiography : the journal of the Working Group on Echocardiography of the European Society of Cardiology

دوره 12 1  شماره 

صفحات  -

تاریخ انتشار 2011