Single-dose gadolinium with magnetization transfer versus triple-dose gadolinium in the MR detection of multiple sclerosis lesions.

نویسندگان

  • J H van Waesberghe
  • J A Castelijns
  • W Roser
  • N Silver
  • T Yousry
  • G J Lycklama à Nijeholt
  • H J Adèr
  • B M Uitdehaag
  • E W Radue
  • C H Polman
  • L Kappos
  • D H Miller
  • F Barkhof
چکیده

PURPOSE To compare the efficacy of single-dose gadolinium with magnetization transfer contrast (MTC) with that of triple-dose gadolinium in detecting enhancing multiple sclerosis lesions. METHODS Twenty-one patients with multiple sclerosis were examined with MR imaging first with 0.1 mmol/kg gadolinium (single dose) and then, after 24 to 72 hours, with 0.3 mmol/kg gadolinium (triple dose). T2-weighted fast spin-echo and T1-weighted spin-echo MR images with and without MTC were obtained before contrast administration followed by either T1-weighted spin-echo images with MTC (single dose) or conventional T1-weighted spin-echo images (triple dose), starting 5, 17, and 29 minutes after contrast administration. All images were evaluated in a blinded fashion and scored in random order by two readers. Outcome parameters included number of enhancing lesions, number of active MR examinations (those containing at least one enhancing lesion), contrast ratio (signal intensity of enhancing lesion divided by signal intensity of normal-appearing white matter), and size of enhancing lesions. RESULTS Eighty-one percent more enhancing lesions and 49% more active MR examinations were detected when a triple dose of gadolinium was used as compared with a single dose. The level of agreement between readers as to the number of enhancing lesions was significantly higher for triple-dose than for single-dose gadolinium. With triple-dose gadolinium, contrast ratios and areas of enhancement increased by 10% and 33%, respectively. Delayed imaging increased the size of the lesion by 11% on single-dose MTC images and by 18% on triple-dose images. CONCLUSION Triple-dose gadolinium is more effective (higher sensitivity and interobserver agreement) than single-dose gadolinium in combination with MTC in detecting enhancing multiple sclerosis lesions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sensitivity of contrast enhanced MRI in multiple sclerosis. Effects of gadolinium dose, magnetization transfer contrast and delayed imaging.

Although clinical end points remain the definitive measure of therapeutic efficacy in multiple sclerosis, more sensitive markers of disease activity are required to screen potential disease-modifying agents. The use of gadolinium contrast-media in MRI studies increases both the reliability and sensitivity of detecting active lesions in multiple sclerosis. We studied three potential methods for ...

متن کامل

Comparison of triple dose versus standard dose gadolinium-DTPA for detection of MRI enhancing lesions in patients with primary progressive multiple sclerosis.

This study was performed to evaluate whether a triple dose of gadolinium-DTPA (Gd-DTPA) increases the sensitivity of brain MRI for detecting enhancing lesions in patients with primary progressive multiple sclerosis (PPMS). T1 weighted brain MRI was obtained for 10 patients with PPMS in two sessions. In the first session, one scan was obtained five to seven minutes after the injection of 0.1 mmo...

متن کامل

Comparison Between Immediate and Delayed Imaging after Gadolinium Chelate Injection for Detecting Enhanced Lesions in Multiple Sclerosis

Background/Objective: Magnetic resonance imaging (MRI) is a noninvasive and valuable method in the diagnosis of Multiple Sclerosis (MS). Compared with other modalities, the sensitivity of MRI for detection of the lesion increases using magnetization transfer (MT) and delayed imaging. Our aim was to compare the two methods in detecting MS lesions. Patients and Methods: In this double-blind clini...

متن کامل

Sensitivity of enhanced MR in multiple sclerosis: effects of contrast dose and magnetization transfer contrast.

BACKGROUND AND PURPOSES New strategies have been developed to improve the sensitivity of contrast-enhanced MR imaging in quantifying disease activity in patients with multiple sclerosis (MS). The goal of the present study was to evaluate the sensitivity of T1-weighted images after injection of a triple dose of contrast material and application of a magnetization transfer (MT) pulse in the detec...

متن کامل

Fingolimod versus High Dose Interferon Beta-1a in Multiple Sclerosis: A Randomized Clinical Trial

Background: High dose Interferon Beta and Fingolimod are efficient in Multiple Sclerosis. Objectives: Comparison the efficacy of these two drugs in patients with treatment failure on low dose interferon beta. Materials and Methods: The MS patients (McDonald criteria 2010) with the history of unbeneficial treatment on low dose interferon beta participated in this randomized clinical trial ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 18 7  شماره 

صفحات  -

تاریخ انتشار 1997