Early detection of peritonitis in continuous ambulatory peritoneal dialysis patients by use of chemiluminescence: evaluation of diagnostic accuracy by receiver-operating characteristic curve analysis.
نویسندگان
چکیده
Continuous ambulatory peritoneal dialysis (CAPD) is now a widely accepted treatment for end-stage renal disease. However, the high incidence of peritonitis is a major complication of CAPD. Polymorphonuclear leukocytes (PMNs) play a major role in antimicrobial response of the host. During phagocytosis, the PMNs undergo a striking increase in oxidative metabolism, known as the respiratory burst, and emit light as chemiluminescence (CL). CL is thus a sensitive measure of PMN oxidative potential and correlates well with antimicrobial activity. In view of the observation of increased susceptibility to infection in CAPD patients, we have studied lucigenin- and luminol-enhanced CL in peritoneal fluids of these patients and assessed the diagnostic accuracy of these tests by ROC curve analysis. ROC curves showed diagnostic accuracies for both tests that were superior to counts of PMNs in the dialysis fluid (P <0.001). At selected cutoff values of 150000 cpm/vial for lucigenin CL and 600000 cpm/vial for luminol CL, sensitivities were 100%. Specificities for lucigenin and luminol CL were 89% and 80%, respectively. Our results suggest that CL measurements can be used as an early marker for the presence of infection in CAPD patients.
منابع مشابه
Application of adjusted-receiver operating characteristic curve analysis in combination of biomarkers for early detection of gestational diabetes mellitus
Introduction: In medical diagnostic field, evaluation of diagnostic accuracy of biomarkers or tests has always been a matter of concern. In some situations, one biomarker alone may not be sufficiently sensitive and specific for prediction of a disease. However, combining multiple biomarkers may lead to better diagnostic. The aim of this study was to assess the performance of combination of bio...
متن کاملReceiver Operating Characteristic (ROC) Curve Analysis for Medical Diagnostic Test Evaluation
This review provides the basic principle and rational for ROC analysis of rating and continuous diagnostic test results versus a gold standard. Derived indexes of accuracy, in particular area under the curve (AUC) has a meaningful interpretation for disease classification from healthy subjects. The methods of estimate of AUC and its testing in single diagnostic test and also comparative studies...
متن کاملThe Role of NGAL in Peritoneal Dialysis Effluent in Early Diagnosis of Peritonitis: Case-Control Study in Peritoneal Dialysis Patients.
BACKGROUND Peritoneal dialysis (PD) is frequently complicated by high rates of peritonitis, which result in hospitalization, technique failure, transfer to hemodialysis, and increased mortality. Early diagnosis, and identification of contributing factors are essential components to increasing effectiveness of care. In previous reports, neutrophil gelatinase-associated lipocalin (NGAL), a lipoca...
متن کاملDiagnostic evaluation of milk lactate dehydrogenase and alkaline phosphatase activities by receiver operating characteristic analysis curve in early lactation of ewes with subclinical mastitis
The aim of the present study was to investigate the diagnostic evaluation of milk lactate dehydrogenase (mLDH) and alkaline phosphatase (mALP) activities by receiver operating characteristic (ROC) analysis curve in early lactation of ewes with subclinical mastitis (SCM) and determine the correlation between number of somatic cell count (SCC) and mLDH and mALP activities. A total of 196 udder ha...
متن کاملCorrelation between Ultrafiltration Coefficient and Effective Lymphatic Absorption Rate in Continuous Ambulatory Peritoneal Dialysis Patients: A Possible Paradigm Shift
Background: The relative contribution of transcapillary water movement and lymphatic reabsorption in peritoneal dialysis (PD) is a critical issue, particularly in patients with ultrafiltration failure (UFF). Based on routine results obtained from the PD Adequest 2.0 software, the present study aimed to re-evaluate the separate effects of transcapillary water movement and lymphatic reabsorption ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry
دوره 44 8 Pt 1 شماره
صفحات -
تاریخ انتشار 1998