Estimation of airway obstruction using oximeter plethysmograph waveform data

نویسندگان

  • Donald H Arnold
  • David M Spiro
  • Renee' A Desmond
  • James S Hagood
چکیده

BACKGROUND Validated measures to assess the severity of airway obstruction in patients with obstructive airway disease are limited. Changes in the pulse oximeter plethysmograph waveform represent fluctuations in arterial flow. Analysis of these fluctuations might be useful clinically if they represent physiologic perturbations resulting from airway obstruction. We tested the hypothesis that the severity of airway obstruction could be estimated using plethysmograph waveform data. METHODS Using a closed airway circuit with adjustable inspiratory and expiratory pressure relief valves, airway obstruction was induced in a prospective convenience sample of 31 healthy adult subjects. Maximal change in airway pressure at the mouthpiece was used as a surrogate measure of the degree of obstruction applied. Plethysmograph waveform data and mouthpiece airway pressure were acquired for 60 seconds at increasing levels of inspiratory and expiratory obstruction. At each level of applied obstruction, mean values for maximal change in waveform area under the curve and height as well as maximal change in mouth pressure were calculated for sequential 7.5 second intervals. Correlations of these waveform variables with mouth pressure values were then performed to determine if the magnitude of changes in these variables indicates the severity of airway obstruction. RESULTS There were significant relationships between maximal change in area under the curve (P < .0001) or height (P < 0.0001) and mouth pressure. CONCLUSION The findings suggest that mathematic interpretation of plethysmograph waveform data may estimate the severity of airway obstruction and be of clinical utility in objective assessment of patients with obstructive airway diseases.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Monitoring respiration rate in PACU patients using the plethysmogram from a pulse oximeter

Introduction Post-operative patients with undiagnosed obstructive sleep apnea are at risk of sudden respiratory failure after receiving anesthesia because of repressed respiratory and hemodynamic responses [1] . While all patients have their oxygen saturation automatically monitor in the Post Anesthesia Care Unit (PACU), few have their respiration rate monitored. The goal of our study is to dev...

متن کامل

Monitoring respiration rate in PACU patients using the plethysmogram from a commercial pulse oximeter

Introduction Post-operative patients with undiagnosed obstructive sleep apnea are at risk of sudden respiratory failure after receiving anesthesia because of repressed respiratory and hemodynamic responses [1]. While all patients have their oxygen saturation monitored in the Post Anesthesia Care Unit (PACU), few have their respiration rate monitored. The respiratory rate could be used to detect...

متن کامل

Comparison of traditional and plethysmographic methods for measuring pulsus paradoxus.

BACKGROUND In the evaluation of patients with acute asthma, pulsus paradoxus (PP) is an objective and noninvasive indicator of the severity of airway obstruction. However, in children PP may be difficult or impossible to measure. Indwelling arterial catheters facilitate the measurement of PP, but they are invasive and generally reserved for critically ill patients. OBJECTIVE To determine the ...

متن کامل

Noninvasive assessment of asthma severity using pulse oximeter plethysmograph estimate of pulsus paradoxus physiology

BACKGROUND Pulsus paradoxus estimated by dynamic change in area under the oximeter plethysmograph waveform (PEP) might provide a measure of acute asthma severity. Our primary objective was to determine how well PEP correlates with forced expiratory volume in 1-second (%FEV1) (criterion validity) and change of %FEV1 (responsiveness) during treatment in pediatric patients with acute asthma exacer...

متن کامل

Pulse Wave Analysis Digital Plethysmography Finger Plethysmography Accelerated Plethysmography Clinical Bottom Line - The Simple Explanation

The digital plethysmograph is a secondary output of the pulse oximeter, which is commonly used to measure arterial blood saturation (SaO2)61. Digital plethysmography provides noninvasive, continuous, and real-time measurement of arterial pressure with infrared light transmitted through a digit (finger or toe)62. This technique acquires the digital volume pulse (DVP), a waveform that estimates p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Respiratory Research

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2005