Air and Water Flowrate Optimisation for a Fan Coil Unit in Heat Pump Systems

نویسندگان

  • Edwards Kilian
  • Donal P. Finn
  • Kilian C. EDWARDS
  • Donal P. FINN
چکیده

The degradation in efficiency of auxiliary components in heating/cooling systems when operating at part load is frequently reported. Through the use of variable speed components, the supplied capacity can be reduced to match the required load and hence reduce unnecessary energy consumption. However, for fan coil units, difficulties can arise when optimizing fan and pump speeds at part load. Practically locating optimal water and air flow rates from readily available information and for varying supplied capacities is necessary, in order to reduce the fan coil power consumption. This research attempts to identify whether optimal fan and pump speeds exist for a fan coil unit and how they can be implemented, in a practical manner, in a system control applications. Using an empirical fan coil and pump model, the total power consumption (fan and pump) for different combinations of fan and pump speeds over a range of capacities was calculated. It was observed that, for a given capacity, an optimal combination of fan and pump speeds exists and there was a significant change in power consumption for different combinations of fan and pump speeds supplying the same capacity. A control strategy is described that utilizes a simple fan coil capacity estimation model, coupled with air and water flow rates, along with nominal design data. The pump speed is optimized using PID control to maintain the space temperature at the chosen set-point, which matches the supplied capacity to the required capacity. At set-time intervals, the capacity estimation model is utilized to optimize the water and air flow rates for the required capacity. The control strategy is evaluated, using a full building simulation model for a daily load profile and is compared to two baseline conditions: for no control of the fancoils/pump combination and for PID circulation control of the pump only. The optimal fan and pump speed control resulted in a 43% and 24% decrease in power consumption with compared to the no control baseline and the PID controlled circulation pump strategy, respectively.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Passive Energy Air-to-Water Heat Pipe Based Heat Exchanger and its Potential of Air Pre-cooling in Air Conditioning Systems for Iran Climate

Air pre-cooling equipment is normally being employed in air-conditioning systems for pre-cooling the ambient outdoor air to enhance the air-conditioning systems performance. In this study, the potential of a passive water-to-air heat pipe based heat exchanger (HPHEX) for air pre-cooling purpose in air-conditioning systems for the high cooling load demanding regions of Iran was investigated. To ...

متن کامل

Design of a Radiant Panel Cooling System for Summer Air Conditioning System

The main objective of this investigation was to design and investigate a radiant panel cooling system on small scale building type (office) under the central Sudan climatic conditions so as to explore the benefits of radiant cooling systems over conventional air conditioning systems (Variable air volume systems). Transient heat conduction of building (finite difference method) was used to evalu...

متن کامل

Enhancement Performance New Generation of CPU Cooling System Using Water-AL2O3 Nanofluid

By increase in the power of computer systems and enhanced power of the components and their temperature, including the central processing unit (CPU), cooling just by the air is not effective and there is need for more powerful systems to cool down and increase the power of the cooling system. In this article simulation of the heat exchanger material of the fluid cooling system has been studied ...

متن کامل

تحلیل جامع اگزرژی یک پمپ حرارتی زمین گرمایی دما پایین برای استفاده در شرایط اقلیمی رامسر

A comprehensive exergy analysis of a suggested heat pump using low temperature geothermal surface water in Ramsar is carried out in this paper. Analytical formulas for exergy loss, exergy efficiency, exergy loss ratio, exergy loss coefficient and thermodynamic perfect degree are presented for whole and every single component of the system. This analysis is done in heating and cooling mood. It i...

متن کامل

Designing Fuzzy Controller for Air Conditioning Systems in order to Save Energy Consumption and Provide Optimal Conditions in Closed Environments (Indoors)

Today air conditioning systems have been considered by all people as one of welfarerequirements in buildings and closed environments. Since a considerable part of energy lossoccurs in ordinary modern systems, new strategies and solutions are developed in the field inorder to save amount of energy consumption and observe environmental considerations. Fuzzycontrol is one of these methods which pr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014