[Ocular pulse amplitude in patients with open-angle glaucoma, normal-tension glaucoma, and ocular hypertensionby dynamic observing tonometry].
نویسندگان
چکیده
PURPOSE The aim of this study was to compare the ocular pulse amplitude (OPA) in patients with different types of glaucoma, and also to evaluate the usefulness of OPA for the elucidation of normal-tension glaucoma (NTG). OPA is thought to reflect choroidal circulation. SUBJECTS Sixty-six patients with normal-tension glaucoma (NTG), 52 patients with primary open angle glaucoma (POAG), 42 with ocular hypertension (OH) and 68 normal controls (NC) were enrolled in this study. METHODS OPA was measured in all participants by dynamic observing tonometry(DOT). The correlation between OPA and the following parameters [IOP, refraction error (Ref), blood pressure, pulse pressure (PP), MD of Humphrey field analyzer 30-2, type of groups] was analyzed by linear and multiple regression analysis (MRA). Multiple logistic regression analysis (MLR) was used to estimate the adjusted odds ratio (OR) for evaluation of the association between OPA (including other factors) and the proportion of NTG. RESULTS In MRA, IOP, Ref (< -3 D), PP and type of groups were significantly associated with OPA. The OPA in NTG was significantly lower than NC (p < 0.05). MLR demonstrated that OPA [OR 0.26 (95% CI, 0.12-0.57), p = 0.001] was associated with increased risk of having NTG. CONCLUSIONS Lower OPA in patients with NTG suggests that there is insufficiency of ocular circulation in NTG. Evaluation of OPA may be useful for the elucidation of the pathogenesis of glaucoma.
منابع مشابه
Ocular pulse amplitude in patients with open angle glaucoma, normal tension glaucoma, and ocular hypertension
Background/aim: Intraocular pressure (IOP) is not a fixed constant value but rather has pulsatile components associated with cardiac action. The SmartLens dynamic observing tonometer (odc, Ophthalmic Development Company AG, Zurich, Switzerland) can measure and record simultaneously IOP and ocular pulse amplitude (OPA). It was the aim of this study to evaluate OPA in patients with primary open a...
متن کاملCorrelation between diurnal variation of intraocular pressure, ocular pulse amplitude and corneal structural properties.
PURPOSE The purpose of this study was to evaluate the fluctuation of intraocular pressure measurements obtained by Goldmann applanation tonometry, dynamic contour tonometry, and corneal compensated non-contact tonometry during office hours in glaucoma and healthy participants. This study also aims at correlating the intraocular pressure fluctuations with fluctuations of corneal hysteresis, cent...
متن کاملSCIENTIFIC CORRESPONDENCE Ocular pulse amplitude in patients with open angle glaucoma, normal tension glaucoma, and ocular hypertension
Background/aim: Intraocular pressure (IOP) is not a fixed constant value but rather has pulsatile components associated with cardiac action. The SmartLens dynamic observing tonometer (odc, Ophthalmic Development Company AG, Zurich, Switzerland) can measure and record simultaneously IOP and ocular pulse amplitude (OPA). It was the aim of this study to evaluate OPA in patients with primary open a...
متن کاملComparison of Ocular Pulse Amplitude Lowering Effects of Preservative-Free Tafluprost and Preservative-Free Dorzolamide-Timolol Fixed Combination Eyedrops
PURPOSE To compare the ocular pulse amplitude (OPA) lowering effects of preservative-free tafluprost and dorzolamide-timolol fixed combination (DTFC) using dynamic contour tonometry. METHODS In total, 66 eyes of 66 patients with normal tension glaucoma (NTG) (n = 34) or primary open angle glaucoma (POAG) (n = 32) were included. Patients were divided into two groups: the preservative-free tafl...
متن کاملOcular pulse amplitude in different types of glaucoma using dynamic contour tonometry: Diagnosis and follow-up of glaucoma
The aim of the present study was to compare the ocular pulse amplitude (OPA) in patients with different types of glaucoma using dynamic contour tonometry (DCT), to evaluate ocular and systemic factors associated with the OPA and to verify whether OPA measured by DCT is an independent predictor for glaucoma diagnosis. A total of 217 eyes of 217 participants in the following five groups were incl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The British journal of ophthalmology
دوره 86 9 شماره
صفحات -
تاریخ انتشار 2002