A randomized evaluation of different approaches to coronary sinus venography during biventricular pacemaker implants.
نویسندگان
چکیده
AIM Biventricular implantation procedures require contrast venography of the coronary sinus. The aim of our study was to evaluate the efficacy and safety of contrast venography obtained by direct manual contrast injection into the guiding catheter, compared with venography obtained after occlusion of the coronary sinus by a Swan-Ganz catheter. METHODS Eighty-three patients were randomly assigned to direct or occlusive venography technique. The primary endpoint was complication rate. The secondary endpoints were rate of and time required for an adequate venography, total dose of contrast medium and total procedure time. RESULTS Four dissections of the coronary sinus were observed with the occlusive venography technique group while no complications were observed with the direct venography technique group (p=0.04). Rate of adequate venography was similar in the two groups (p=NS). The time needed for coronary sinus venography and the total dose of contrast medium was significantly lower in the direct venography technique group compared with the alternative (p<0.0001 and p=0.003, respectively); the total procedure time was not significantly different between the two groups (p=NS). CONCLUSIONS The direct venography technique shows a significantly lower incidence of complications and should be considered to be the first line approach to coronary sinus venography during biventricular pacemaker implantation.
منابع مشابه
MRI for Visualization of Coronary Vein Branches Used for Pacemaker Lead Implantation
Purpose Approximately one third of all patients who undergo Cardiac Resynchronization Therapy (CRT) using a biventricular pacemaker do not benefit from the procedure [1]. Studies have shown that the location of the left ventricular (LV) lead plays an important role in dictating whether patients benefit from the procedure [2,3]. Patients benefit most when the LV lead is placed in the latest cont...
متن کاملMajor dissection of the coronary sinus and its tributaries during lead implantation for biventricular stimulation: angiographic follow-up.
Dissection of the coronary sinus during lead implantation for biventricular pacemaker implantation in patients with advanced heart failure is a serious complication that has occasionally been reported. We report on the clinical outcome and angiographic follow-up in a series of 7 patients with acute major dissection from 103 consecutive attempts (incidence 6.8%). Serial echocardiography was perf...
متن کاملFeasibility of cardiac resynchronization therapy in a patient with complex congenital heart disease and dextrocardia, facilitated by cardiac computed tomography and coronary sinus venography.
We describe a case with pacemaker implantation for cardiac resynchronization therapy (CRT) in a patient with complex congenital heart disease, facilitated by cardiac computed tomography (CT) and coronary sinus (CS) venography. A 37-year-old male presented with congenitally corrected transposition of the great arteries and mesocardia, along with a history of two open heart surgeries (closure of ...
متن کامل[Technical aspects of coronary sinus catheterization based on the atrial component of the intracavitary electrogram and radiological anatomy during the implantation procedure of a biventricular pacemaker].
OBJECTIVE To present a technical proposal based on the experience of 130 implantations using a simplified technique for coronary sinus catheterization, based on the atrial component of the intracavitary electrogram and radiological anatomy. METHODS From October, 2001 to October, 2004, 130 biventricular pacemaker implantations were performed, using radiological anatomy and observation of the i...
متن کاملTransvenous biventricular defibrillation halves energy requirements in patients.
BACKGROUND Defibrillation thresholds (DFT) with standard implantable cardioverter-defibrillator leads in the right ventricle (RV) may be determined by weak shock field intensity in the myocardium of the left ventricle (LV). Adding a shocking electrode in a coronary vein on the middle of the LV free wall, thereby establishing biventricular defibrillation, substantially reduced defibrillation req...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology
دوره 7 1 شماره
صفحات -
تاریخ انتشار 2005