Analyzing and Comparing the Hot-spot Thermal Models of HV/LV Prefabricated and Outdoor Oil-Immersed Power Transformers
نویسنده
چکیده
The most important parameter in transformers life expectancy is the hot-spot temperature level which accelerates the rate of aging of the insulation. The aim of this paper is to present thermal models for transformers loaded at prefabricated MV/LV transformer substations and outdoor situations. The hot-spot temperature of transformers is studied using their top-oil temperature rise models. The thermal models proposed for hot-spot and top-oil temperatures of different operating situations are compared. Since the thermal transfer is different for indoor and outdoor transformers considering their operating conditions, their hot-spot thermal models differ from each other. The proposed thermal models are verified by the results obtained from the experiments carried out on a typical 1600 kVA, 30 /0.4 kV, ONAN transformer for both indoor and outdoor situations. Keywords—Hot-spot Temperature, Dynamic Thermal Model, MV/LV Prefabricated, Oil Immersed Transformers
منابع مشابه
Different Electric Vehicle Charging Strategies to avoid Reducing the Insulation Oil Lifetime of Distribution Transformers
Abstract: The widespread presence of uncontrolled electric vehicles causes overloading of distribution network equipment. One of these equipments is distribution transformer, which should pay attention to overloading and reducing lifetime of this equipment due to charging of electric vehicles. First, strategies have been proposed to investigate the effect of electric vehicle penetration level a...
متن کاملCombination of Support Vector Regression with Particle Swarm Optimization for Hot-spot temperature prediction of oil-immersed power transformer
The life expectancy and load capacity of oil-immersed power transformers are intimately associated with the winding hot spot temperature (HST). Thus, accurately predicting HSTs is essential in evaluating the life expectancy of power transformers and in preventing thermal failure. Previously, support vector machine (SVM) has been successfully employed to solve the regression problem of nonlinear...
متن کاملHot Spot Temperature and Grey Target Theory Based Dynamic Modelling for Reliability Assessment of Transformer Oil-Paper Insulation Systems: A Practical Case Study
This paper develops a novel dynamic correction method for the reliability assessment of large oil-immersed power transformers. First, with the transformer oil-paper insulation system (TOPIS) as the target of evaluation and the winding hot spot temperature (HST) as the core point, an HST-based static ageing failure model is built according to the Weibull distribution and Arrhenius reaction law, ...
متن کاملReliability Analysis and Overload Capability Assessment of Oil-Immersed Power Transformers
Smart grids have been constructed so as to guarantee the security and stability of the power grid in recent years. Power transformers are a most vital component in the complicated smart grid network. Any transformer failure can cause damage of the whole power system, within which the failures caused by overloading cannot be ignored. This research gives a new insight into overload capability ass...
متن کاملPower transformers health index calculation using reliability methods for the case study of the Dez Dam and Karkheh Dam hydro power plants
Transformers in power plants act as intermediaries between the power plant and the power grid, which are affected by electrical stresses such as switching, thermal stresses such as overload and arc, and chemical reactions in the dielectric oil. Acid and moisture components cause deterioration of transformer oil and paper insulation. Condition assessment of transformers is a method to predict an...