Three-dimensional transrectal ultrasound guided high-dose-rate prostate brachytherapy: A comparison of needle segmentation accuracy with two-dimensional image guidance.

نویسندگان

  • William Thomas Hrinivich
  • Douglas A Hoover
  • Kathleen Surry
  • Chandima Edirisinghe
  • Jacques Montreuil
  • David D'Souza
  • Aaron Fenster
  • Eugene Wong
چکیده

PURPOSE Conventional transrectal ultrasound guided high-dose-rate prostate brachytherapy (HDR-BT) uses an axially acquired image set for organ segmentation and 2D sagittal images for needle segmentation. Sagittally reconstructed 3D (SR3D) transrectal ultrasound enables both organ and needle segmentation and has the potential to reduce organ-needle alignment uncertainty. This study compares the accuracy of needle tip localization between the conventional 2D sagittally assisted axially reconstructed (SAAR) and SR3D approaches. METHODS AND MATERIALS Twelve patients underwent SAAR-guided HDR-BT, during which SR3D images were acquired for subsequent segmentation and analysis. A total of 183 needles were investigated. Needle end-length measurements were taken, providing a gold standard for insertion depths. Dosimetric impact of insertion depth errors (IDEs) on clinical treatment plans was assessed. RESULTS SR3D guidance provided statistically significantly smaller IDEs than SAAR guidance with a mean ± SD of -0.6 ± 3.2 mm and 2.8 ± 3.2 mm, respectively (p < 0.001). Shadow artifacts were found to obstruct the view of some needle tips in SR3D images either partially (12%) or fully (10%); however, SR3D IDEs had a statistically significantly smaller impact on prostate V100% than SAAR IDEs with mean ± SD decreases of -1.2 ± 1.3% and -6.5 ± 6.7%, respectively (p < 0.05). CONCLUSIONS SR3D-guided HDR-BT eliminates a source of systematic uncertainty from the SAAR-guided approach, providing decreased IDEs for most needles, leading to a significant decrease in dosimetric uncertainty. Although imaging artifacts can limit the accuracy of tip localization in a subset of needles, we identified a method to mitigate these artifacts for clinical implementation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Needle segmentation using 3D Hough transform in 3D TRUS guided prostate transperineal therapy.

PURPOSE Prostate adenocarcinoma is the most common noncutaneous malignancy in American men with over 200,000 new cases diagnosed each year. Prostate interventional therapy, such as cryotherapy and brachytherapy, is an effective treatment for prostate cancer. Its success relies on the correct needle implant position. This paper proposes a robust and efficient needle segmentation method, which ac...

متن کامل

A new CT prostate segmentation for CT-based HDR brachytherapy

High-dose-rate (HDR) brachytherapy has become a popular treatment modality for localized prostate cancer. Prostate HDR treatment involves placing 10 to 20 catheters (needles) into the prostate gland, and then delivering radiation dose to the cancerous regions through these catheters. These catheters are often inserted with transrectal ultrasound (TRUS) guidance and the HDR treatment plan is bas...

متن کامل

Prostate biopsies guided by three-dimensional real-time (4-D) transrectal ultrasonography on a phantom: comparative study versus two-dimensional transrectal ultrasound-guided biopsies

OBJECTIVE This study evaluated the accuracy in localisation and distribution of real-time three-dimensional (4-D) ultrasound-guided biopsies on a prostate phantom. METHODS A prostate phantom was created. A three-dimensional real-time ultrasound system with a 5.9MHz probe was used, making it possible to see several reconstructed orthogonal viewing planes in real time. Fourteen operators perfor...

متن کامل

High-dose-rate Brachytherapy for Prostate Cancer

Introduction/Background Over the last 2 decades, significant technical advancements have improved the delivery of prostate brachytherapy. The transrectal ultrasound-guided implant technique is the backbone of modern prostate brachytherapy. Whether it is permanent or temporary, ie, low-dose-rate (LDR) or high-dose-rate (HDR), respectively, both use similar image-guided techniques for inserting s...

متن کامل

AAPM Task Group 128: quality assurance tests for prostate brachytherapy ultrasound systems.

While ultrasound guided prostate brachytherapy has gained wide acceptance as a primary treatment tool for prostate cancer, quality assurance of the ultrasound guidance system has received very little attention. Task Group 128 of the American Association of Physicists in Medicine was created to address quality assurance requirements specific to transrectal ultrasound used for guidance of prostat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Brachytherapy

دوره 15 2  شماره 

صفحات  -

تاریخ انتشار 2016