Effects of Different Ligature Materials on Friction in Sliding Mechanics
نویسندگان
چکیده
BACKGROUND During orthodontic tooth movement friction occurs at the bracket wire interface. Out of the total force applied to the tooth movement, some of it is dissipated as friction, and the remainder is transferred to the supporting structures of the tooth to mediate tooth movement. However many factors affect friction, and method of arch wire ligation being an important contributing factor. Hence, this study was carried out to evaluate the effects of different ligature materials on friction in sliding mechanics and to compare the effect of environment (dry and wet) on friction produced in sliding mechanics. MATERIALS AND METHODS The evaluation of friction between the bracket and the archwire consisted of a simulated half arch fixed appliance with archwire ligated in a vertical position. Four 0.022" maxillary stainless steel premolar brackets having a - 0° torque and 0° angulation were aligned with a 0.019" × 0.025" stainless steel arch wire onto a rigid Plexiglass sheet. The movable test bracket was fitted with a 10 mm long, 0.045" thick stainless steel power arm on the bonding surface. Testing was performed on a Hounsfield material testing machine. A total of 100 g weight was suspended from the power arm and the load needed to move the bracket over the distance of not <4 mm across the central span was recorded separately. Fifteen representative readings were taken with one reading per test sample. RESULTS The results showed that the mean frictional force of different groups in dry and wet state was statistically significantly different. The mean frictional force in a dry state was statistically significantly higher than wet state in elastomeric group. CONCLUSION The type of ligation material and environment significantly affected the degree of friction generated during sliding mechanics. Teflon coated stainless steel ligatures produced the least friction among the materials tested in both dry and wet conditions and there was no significant effect on friction in this group caused due to lubrication.
منابع مشابه
A comparative study to evaluate the effects of ligation methods on friction in sliding mechanics using 0.022" slot brackets in dry state: An In-vitro study.
BACKGROUND Friction between archwires and brackets is assuming greater importance for finishing with increased use of sliding mechanics in orthodontics as friction impedes the desired tooth movement. The following study is conducted to compare and evaluate the effect of ligation on friction in sliding mechanics using 0.022" slot bracket in dry condition. MATERIALS & METHODS In the study 48 co...
متن کاملFriction Forces during Sliding of Various Brackets for Malaligned Teeth: An In Vitro Study
AIMS To measure the friction force generated during sliding mechanics with conventional, self-ligating (Damon 3 mx, Smart Clip, and Time 3) and low-friction (Synergy) brackets using different archwire diameters and ligating systems in the presence of apical and buccal malalignments of the canine. METHODS An experimental setup reproducing the right buccal segment of the maxillary arch was desi...
متن کاملEfficacy of Super Slick elastomeric modules in reducing friction during sliding: a comparative in vitro study.
AIM To evaluate and compare the frictional resistance produced by Super Slick modules during sliding with four different types of brackets and four ligature types both in conventional and figure-of-8 ligation method with saliva as lubricant. MATERIALS AND METHODS The frictional resistance was evaluated by using four different ligatures on 0.019" × 0.025" stainless steel (SS) archwires using f...
متن کاملInfluence of ligation method on friction resistance of lingual brackets with different second-order angulations: an in vitro study
OBJECTIVE To evaluate stainless steel archwire static friction in active and passive self-ligating lingual and conventional brackets with second-order angulations. METHODS Two conventional lingual brackets for canines (STb light/Ormco; PSWb/Tecnident), and two self-ligating brackets, one active (In-Ovation L/GAC) and the other passive (3D/ Forestadent), were evaluated. A stainless steel archw...
متن کاملPhysical and chemical properties of orthodontic brackets after 12 and 24 months: in situ study
OBJECTIVE The aim of this article was to assess how intraoral biodegradation influenced the surface characteristics and friction levels of metallic brackets used during 12 and 24 months of orthodontic treatment and also to compare the static friction generated in these brackets with four different methods of the ligation of orthodontic wires. MATERIAL AND METHODS Seventy premolar brackets as ...
متن کامل