AC-DC Transfer Standard Measurements and Generalized Compensation with the AC Josephson Voltage Standard
نویسندگان
چکیده
We present ac-dc transfer standard measurements using the NIST pulse-driven ac Josephson voltage standard source. We have investigated the frequency dependence for several output voltages up to 200 mV for frequencies from 2.5 kHz to 100 kHz. We found that as the frequency increases, the ac-dc differences for the two arrays on the same chip do not agree. We investigated different attempts of improvement and the deviation in ac-dc difference was reduced by more than 60 %. We also demonstrate ten-fold higher output voltages and improved operating margins for non-sinusoidal waveforms, by implementing a more general current bias to the arrays (having the same harmonic content as that of the synthesized arbitrary waveform). Index Terms – AC metrology, Josephson voltage standard, precision ac source, quantum standards.
منابع مشابه
AC-DC Transfer Standard Measurements Using An AC Josephson Voltage Standard
NIST is implementing the Josephson arbitrary waveform synthesizer as an ac Josephson Voltage Standard (ACJVS). Over the past few years we have demonstrated precise measurements of synthesized sine waves at rms voltage amplitudes up to 170 mV. The system can generate a variety of precision voltage outputs including dc voltages and ac sinewaves, so it can be used as a quantum-based voltage source...
متن کاملOperating Margin Measurements for an AC Josephson Voltage Standard
For a number of years, NIST has been developing a Josephson arbitrary waveform synthesizer as an ac Josephson Voltage Standard (ACJVS). The effort has primarily focused on increasing the output voltage to practical levels. Recent advances in circuit design and superconducting integrated circuit fabrication have enabled us for the first time to demonstrate waveforms with a 242 mV peak voltage. T...
متن کاملAn AC Josephson Voltage Standard for AC-DC Transfer-Standard Measurements
In order to improve the National Institute of Standards and Technology (NIST) low-voltage calibration service for thermal-voltage converters, we have constructed an ac-Josephsonvoltage-standard (ACJVS) system that can synthesize accurate rms voltages of up to 100 mV. Using this system, we synthesized dc voltages and audio-frequency sine waves in order to measure ac–dc differences on the 22 mV a...
متن کاملDevelopment of a High-precision Ac-dc Transfer Standard Using the Fast-reversed Dc Method
The ac-dc transfer standard is one of the basic electrical standards, by which the ac voltage and ac current are deduced from their dc counterparts in the frequency range between 10 Hz and 1 MHz [1,2]. The dc voltage standards are established using a Josephson voltage standard with uncertainty better than 10-7 [3-5]. The ac voltage standard in the frequency range 10 Hz to 1 MHz are derived from...
متن کاملDevelopment of Josephson Voltage Standards
Exciting applications of superconductivity are based on the macroscopic quantum state which exists in a superconductor. In this chapter we investigate the behaviour of junctions consisting of two weakly coupled superconductors. These junctions are nowadays called Josephson junctions1 (Josephson, 1962). The macroscopic quantum state results in an exceptional behaviour of these Josephson junction...
متن کامل