First Results from Two Novel In-vacuum Magnetic Field Measurement Devices as Built at Hzb
نویسندگان
چکیده
The characterization of cryogenic in vacuum permanent magnet undulators with periods less than 20 mm and correspondingly narrow gaps requires new in-vacuum measurement systems. The positioning accuracy of the HZB in-vacuum Hallprobe bench has substantially been improved (a few μm) with appropriate feedback systems. A new in-vacuum cable tray has been developed. Another system for field integral measurements, an in-vacuum moving wire, is under commissioning. Both devices are presented. IN-VACUUM HALLPROBE BENCH Positioning Accuracy The general layout of the bench has been presented a few years ago [1]. The accuracy of the device is based on five piezo actuators and five optical measurement devices for feedback: three laser interferometer channels and two 2D-position sensitive detectors. The positioning accuracy of the in-vacuum Hallprobe bench has been successfully tested over a length of 0.5 m with the laser interferometer feedback switched on [2]. The range was limited because the cable tray was not operational, yet. Meanwhile extensive tests of the new in-vacuum cable tray have been performed. The tests will be described in the next section.
منابع مشابه
The Measurement of Low Frequency Magnetic Field of Two Kinds of GSM900 Mobile Phone
Introduction: The use of mobile communication systems has dramatically increased over the past decade. Although many studies have been performed to determine the effect of radio frequency (RF) but less attention has been paid to the possible biological impact of exposure to extremely low frequency (ELF) components. The objective of this study is two folds. One is to design the ...
متن کاملA Novel Transformer-Based Single-to-Three Phase Conversion Technique Using Rotating Magnetic Field Theory
This paper presents a new single to three phase converter using rotating magnetic field transformer. Conventional transformers have been used in many converters aiming at supplementary improvements and they usually have no critical effect on the conversion technique. In this paper, the conversion technique is based on a special rotating magnetic field transformer in which there are two windings...
متن کاملFirst Tests with a Local and Integral Magnetic Field Measurement Setup for Conduction Cooled Superconducting Undulator Coils
During the last years improvements in magnetic field measurement technology of conventional, i.e. permanent magnet based insertion devices (IDs), made significant progress and pushed the capabilities of synchrotron light sources. For superconducting IDs similar developments are now needed to perform precise measurements of local magnetic fields and field integrals. We follow this aim within our...
متن کاملMagnetic Performance of Insertion Devices at the Advanced Photon Source
The insertion devices (IDs) at the Advanced Photon Source have been magnetically tuned to minimize the integrals of the field through the devices and to minimize the variation of those integrals with gap, with a goal of not perturbing the stored particle beam. Measurements of the particle beam motion as the ID gap was changed found that the closed-orbit distortion was better than the requiremen...
متن کاملQualitative Variations of Macrobrachium nipponense Tiny Shrimp from Bandar Anzali International Lagoon by Three Dryers during Six Months Storage
Background and Objectives: With recent declines in aquaculture resources, the use of new protein sources has expanded; as a result, it is necessary to use tiny shrimp of Anzali International Lagoon for its high nutritional value. Materials & Methods: Macrobrachium nipponense non-native shrimp, after catching and washing with cold water, was dried in cabinet, oven and under vacuum dryers at 7...