Anthracycline-induced cardiotoxicity: cardiac monitoring by continuous wave-Doppler ultrasound cardiac output monitoring and correlation to echocardiography.
نویسندگان
چکیده
BACKGROUND Anthracyclines are agents with a wellknown cardiotoxicity. The study sought to evaluate the hemodynamic response to an anthracycline using realtime continuous-wave (CW)-Doppler ultrasound cardiac output monitoring (USCOM) and echocardiography in combination with serum biomarkers. METHODS 50 patients (26 male, 24 female, median age 59 years) suffering from various types of cancer received an anthracycline-based regimen. Patients' responses were measured at different time points (T0 prior to infusion, T1 6 h post infusion, T2 after 1 day, T3 after 7 days, and T4 after 3 months) with CW-Doppler ultrasound (T0-T4) and echocardiography (T1, T4) for hemodynamic parameters such as stroke volume (SV; SVUSCOM ml) and ejection fraction (EF; EFechocardiography%) and with NT-pro-BNP and hs-Troponin T (T0-T4). RESULTS During the 3-month observation period, the relative decrease in the EF determined by echocardiography was -2.1% (▵T0-T4, T0 71 ± 7.8%, T4 69.5 ± 7%, p = 0.04), whereas the decrease in SV observed using CW-Doppler was -6.5% (▵T0-T4, T0 54 ± 19.2 ml, T4 50.5 ± 20.6 ml, p = 0.14). The kinetics for serum biomarkers were inversely correlated. CONCLUSIONS Combining real-time CW-Doppler USCOM and serum biomarkers is feasible for monitoring the immediate and chronic hemodynamic changes during an anthracycline-based regimen; the results obtained were comparable to those from echocardiography.
منابع مشابه
Cardiotoxicity After Anthracycline Treatment in Survivors of Adult Cancers: Monitoring by USCOM, Echocardiography and Serum Biomarkers
Background Anthracyclines are agents with a well known documented anti-tumoral activity. Cardiac side effects are the principal toxicity. Here we evaluate and monitor the onset of late anthracycline-induced cardiotoxicity with real-time CW-Doppler ultrasound cardiac output monitoring (USCOM®) and echocardiography in combination with serum biomarkers. Methods Fifty-two patients without cardiac...
متن کاملInfluence of injection rates of calibrating standard solution on monitoring pulse indicator continuous cardiac output
OBJECTIVE This study aimed to investigate the influence of injection rates of calibrating standard solution on monitoring pulse indicator continuous cardiac output (PICCO, made in Germany), and thereby to provide significant references for clinical practice. METHODS A total of 108 critical patients in stroke intensive care unit were identified. All these participants received transesophageal ...
متن کاملCancer therapy and cardiotoxicity: The need of serial Doppler echocardiography
Cancer therapy has shown terrific progress leading to important reduction of morbidity and mortality of several kinds of cancer. The therapeutic management of oncologic patients includes combinations of drugs, radiation therapy and surgery. Many of these therapies produce adverse cardiovascular complications which may negatively affect both the quality of life and the prognosis. For several yea...
متن کاملNoninvasive early detection of anthracycline‐induced cardiotoxicity in patients with hematologic malignancies using the phased tracking method
Anthracyclines are among the most effective and widely used anticancer drugs; however, their use is limited by serious cardiotoxicity. Early detection is necessary to prevent the high mortality rate associated with heart failure (HF). We evaluated cardiac function in 142 patients using conventional echocardiography and the phased tracking method (PTM), which was measured using the minute vibrat...
متن کاملContinuous and Cuffless Blood Pressure Monitoring Based on ECG and SpO2 Signals By Using Microsoft Visual C Sharp
Background: One of the main problems especially in operating room and monitoring devices is measurement of Blood Pressure (BP) by sphygmomanometer cuff.Objective: In this study we designed a new method to measure BP changes continuously for detecting information between cuff inflation times by using vital signals in monitoring devices. This will be achieved by extraction of the time difference ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Onkologie
دوره 35 5 شماره
صفحات -
تاریخ انتشار 2012