How much of the intraaortic balloon volume is displaced toward the coronary circulation?
نویسندگان
چکیده
OBJECTIVE During intraaortic balloon inflation, blood volume is displaced toward the heart (V(tip)), traveling retrograde in the descending aorta, passing by the arch vessels, reaching the aortic root (V(root)), and eventually perfusing the coronary circulation (V(cor)). V(cor) leads to coronary flow augmentation, one of the main benefits of the intraaortic balloon pump. The aim of this study was to assess V(root) and V(cor) in vivo and in vitro, respectively. METHODS During intraaortic balloon inflation, V(root) was obtained by integrating over time the aortic root flow signals measured in 10 patients with intraaortic balloon assistance frequencies of 1:1 and 1:2. In a mock circulation system, flow measurements were recorded simultaneously upstream of the intraaortic balloon tip and at each of the arch and coronary branches of a silicone aorta during 1:1 and 1:2 intraaortic balloon support. Integration over time of the flow signals during inflation yielded V(cor) and the distribution of V(tip). RESULTS In patients, V(root) was 6.4% +/- 4.8% of the intraaortic balloon volume during 1:1 assistance and 10.0% +/- 5.0% during 1:2 assistance. In vitro and with an artificial heart simulating the native heart, V(cor) was smaller, 3.7% and 3.8%, respectively. The distribution of V(tip) in vitro varied, with less volume displaced toward the arch and coronary branches and more volume stored in the compliant aortic wall when the artificial heart was not operating. CONCLUSION The blood volume displaced toward the coronary circulation as the result of intraaortic balloon inflation is a small percentage of the nominal intraaortic balloon volume. Although small, this percentage is still a significant fraction of baseline coronary flow.
منابع مشابه
Influence of timing of intraaortic balloon placement in cardiac surgical patients.
OBJECTIVE The study objective was to evaluate the association between timing of intraaortic balloon pump insertion and outcomes in patients undergoing cardiac surgery. METHODS All patients aged 18 years or more who underwent coronary artery bypass surgery, cardiac valve surgery, or thoracic aortic surgery between January 2002 and December 2007 were included. Data were obtained from cardiac su...
متن کاملIntraaortic balloon pumping for control of recurrent myocardial ischemia.
Eleven patients were studied because of recurrent angina at rest. In five cases ischemic pain developed 3-10 days after acute myocardial infarction. Pain recurred in all cases despite therapy with bedrest, oxygen, heparin anticoagulation, nitrates, and whenever possible, beta blockade. Intraaortic balloon pumping with a 30-cc balloon prevented ischemia in nine patients and markedly reduced the ...
متن کاملMyocardial free-wall rupture after acute infarction: survival aided by percutaneous intraaortic balloon counterpulsation.
After his first acute myocardial infarction, a 69-year-old male suffered the usually lethal complication of ventricular free-wall rupture. Early suspicion of possible rupture and immediate percutaneous insertion of an intraaortic balloon pump assist device afforded sufficient hemodynamic stability to proceed with cardiac catheterization. The diagnosis of ventricular free-wall rupture was confir...
متن کاملEffect of intraaortic balloon pumping on left ventricular function in patients with persistent ST segment elevation after revascularization for acute myocardial infarction.
The purpose of the present study was to assess the impact of intraaortic balloon pumping (IABP) in patients with persistent ST elevation who underwent revascularization within 6 h of their first acute anterior myocardial infarction (AMI). Persistent ST elevation after revascularization was defined as being > or =50% of the initial value on return to the coronary care unit. Twenty-four patients ...
متن کامل2-D ECHO IN EXPERIMENTAL CORONARY STENOSISIPandian and Kerber
(with carbon dioxide) in the aortaa mechanical assistance to the failing ciruclation. Am Heart J 63: 669, 1962 24. Braunwald E, Covell JW, Moroko PR, Ross J: Effects of drugs and of counterpulsation on myocardial oxygen consumption: observations on the ischemic heart. Circulation 40 (suppl IV): IV-220, 1969 25. Powell WJ, Daggett WM, Magro AE, Bianco JA, Buckley MJ, Sanders CA, Kantrowitz AR, A...
متن کامل