Ten Years’ Follow-Up on Combined Palmar and Dorsal Internal Fixation of Complex Distal Radius Fractures

نویسندگان

  • Lukas Daniel Iselin
  • Anne-Sophie Massy-Budmiger
  • Raoul A. Droeser
  • Tobias R. Mett
  • Reto Babst
  • Daniel A. Rikli
چکیده

Complex distal intra-articular radial fractures (AO Type C3) are rare, but are life-changing injuries. They are usually related to high-velocity trauma mechanisms in a working male population.We surveyed a cohort of these fractures treated in our institution to assess the functional long-term outcome.Twelve consecutive patients with comminuted intra-articular distal radial fractures were treated at our institution. Osteosynthesis was performed by a single senior surgeon with volar and dorsal extended approaches. The intermediate and final control included conventional X-ray, range of motion (ROM), grip strength, and the Disabilities of the Arm, Shoulder, and Hand index (DASH), as well as the Patient-rated Wrist Evaluation (PRWE) score for functional outcome at 1 and 10 years' of follow-up.At 10 years' follow-up, anatomic reconstruction with a step or gap of <1 mm was achieved in 10 of the 12 above-mentioned patients, whereas 2 patients were lost to follow-up. ROM was good to excellent in 8 patients. Median grip strength was 107% of the contralateral side. Median DASH-Index and PRWE were 2.3 and 6 respectively, at 10 years. Eight patients returned to premorbid heavy labor. One patient was retired at the time of injury.Combined volar and dorsal approaches allow achieving anatomical reconstruction in comminuted intra-articular distal radius fractures and reveal good functional outcomes at intermediate and long-time follow-up.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fracture heuristics: surgical decision for approaches to distal radius fractures. A surgeon’s perspective

Introduction: The aim of the present study is to develop a heuristic that could replace the surgeon's analysis for the decision on the operative approach of distal radius fractures based on simple fracture characteristics. Patients and methods: Five hundred distal radius fractures operated between 2011 and 2014 were analyzed for the surgeon's decision on the approach used. The 500 distal radius...

متن کامل

Percutaneous pinning versus pin-in-plaster for treatment of distal radius fractures

Background: Distal radius fractures constitute 17% of all fractures and 75% of forearm fractures in adults. Due to the vital role of the hands in a wide range of daily tasks, quick recovery and fewer complications for the patients are important. The purpose of this study was to compare the two common treatments of distal radius fractures namely, percutaneous pinning and pin-in-plaster. Methods...

متن کامل

Locking versus nonlocking palmar plate fixation of distal radius fractures.

This study compared functional and radiological outcomes after treatment of extension-type distal radius fractures with conventional titanium nonlocking T-plates or titanium 1.5-mm locking plates. A total of 60 patients were included and followed for 4 to 7 years after receiving nonlocking T-plates (group A; n=30) or locking plates (group B; n=30) with and without dorsal bone grafting. Bone gra...

متن کامل

Analysis of soft-tissue complications of volar plate fixation for managing distal radius fractures and clinical effect while preserving pronator quadratus.

The aim of the study was to analysis soft-tissue complications of volar plate fixation and it's prevention strategies along with exploring clinical effects of preserving pronator quadratus (PQ) muscle. From February 2011 to February 2013, sixty-five patients with distal radius fracture underwent open reduction and internal fixation with the volar locking palmar plates. The group with preserving...

متن کامل

Volar fixation for dorsally displaced fractures of the distal radius: a preliminary report.

Using a volar approach to avoid the soft tissue problems associated with dorsal plating, we treated a consecutive series of 29 patients with 31 dorsally displaced, unstable distal radial fractures with a new fixed-angle internal fixation device. At a minimal follow-up time of 12 months the fractures had healed with highly satisfactory radiographic and functional results. The final volar tilt av...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 95  شماره 

صفحات  -

تاریخ انتشار 2016