Imposed power of breathing associated with use of an impedance threshold device.

نویسندگان

  • Ahamed H Idris
  • Victor A Convertino
  • Duane A Ratliff
  • Donald F Doerr
  • Keith G Lurie
  • Andrea Gabrielli
  • Michael J Banner
چکیده

OBJECTIVE To measure the imposed power of breathing (imposed work of breathing per minute) associated with spontaneous breathing through an active impedance threshold device and a sham impedance threshold device. DESIGN Prospective randomized blinded protocol. SETTING University medical center. PATIENTS Nineteen healthy, normotensive volunteers (10 males, 9 females, age range 20-56 y, mean +/- SD weight 54.8 +/- 7.7 kg for females, 84 +/- 8 kg for males). METHODS The volunteers completed 2 trials of breathing through a face mask fitted with an active impedance threshold device set to open at -7 cm H(2)O pressure, or with a sham impedance threshold device, which was identical to the active device except that it did not contain an inspiratory threshold pressure valve diaphragm. Spontaneous breathing frequency (f), tidal volume (V(T)), exhaled minute ventilation, inspiratory pressure, and inspiratory time were measured with a respiratory monitor, and the data were directed to a laptop computer for real-time calculation of the imposed power of breathing. RESULTS There were no significant differences in heart rate, respiratory rate, tidal volume, and minute ventilation, with and without inspiratory impedance. For the sham and active impedance threshold device groups, respectively, the mean +/- SD imposed power of breathing values were 0.92 +/- 0.63 J/min and 8.18 +/- 4.52 J/min (p < 0.001), the mean +/- SD inspiratory times were 1.98 +/- 0.86 s and 2.97 +/- 1.1 s (p = 0.001), and the mean +/- SD inspiratory airway/mouth pressures were -1.1 +/- 0.6 cm H(2)O and -11.7 +/- 2.4 cm H(2)O (p < 0.001). CONCLUSIONS Breathing through an active impedance threshold device requires significantly more power than breathing through a sham device. All subjects tolerated the respiratory work load and were able to complete the study protocol.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hemodynamics associated with breathing through an inspiratory impedance threshold device in human volunteers.

OBJECTIVE Increased negative intrathoracic pressure during spontaneous inspiration through an impedance threshold device (ITD) causes elevated arterial blood pressure in humans. This study was performed to determine whether the acute increase in blood pressure induced by breathing through an ITD is associated with increased stroke volume and cardiac output. DESIGN Randomized, blinded, control...

متن کامل

Use of an impedance threshold device to treat severe hypotension in a pregnant woman: case report and review of the literature.

BACKGROUND Impedance threshold device technology harnesses the patient's normal physiological mechanisms to increase circulation during hypotensive crises. We report the first clinical use of one version of this device on a spontaneously breathing hypotensive pregnant woman. OBJECTIVE The objective of our study was to report this case to help Emergency Medical Service rescue personnel to noni...

متن کامل

The Effect of Motivational Abdominal Breathing Device on Breathing Patterns and Shortness of Breath in Patients with Chronic Obstructive Pulmonary Disease

Background and purpose: Despite the high prevalence of chronic obstructive pulmonary disease, There haven,t been definite curative treatment for the disease and focus of treatment has directed towards pulmonary rehabilitation as an effective non-drug treatments. this study were performed to determine the effect of motivational abdominal breathing device on breathing pattern and dyspnea of chron...

متن کامل

Distance-Aware Beamforming for Multiuser Secure Communication Systems

Typical cryptography schemes are not well suited for low complexity types of equipment, e.g., Internet of things (IoT) devices, as they may need high power or impose high computational complexity on the device. Physical (PHY) layer security techniques such as beamforming (in multiple antennas systems)  are possible alternatives to provide security for such applications. In this paper, we consid...

متن کامل

Breathing through an inspiratory threshold device improves stroke volume during central hypovolemia in humans.

Inspiratory resistance induced by breathing through an impedance threshold device (ITD) reduces intrathoracic pressure and increases stroke volume (SV) in supine normovolemic humans. We hypothesized that breathing through an ITD would also be associated with a protection of SV and a subsequent increase in the tolerance to progressive central hypovolemia. Eight volunteers (5 men, 3 women) were i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Respiratory care

دوره 52 2  شماره 

صفحات  -

تاریخ انتشار 2007