Initial Evaluation on Subsidence of Cemented Collarless Polished Tapered Stem Applied to the Patients with Narrow Femoral Medullar Canal

نویسندگان

  • Katsuyuki Dairaku
  • Masaji Ishii
  • Shinji Kobayashi
  • Hiroyuki Kawaji
  • Kan Sasaki
  • Yuya Takakubo
  • Michiaki Takagi
چکیده

PURPOSE The geometry of the proximal femur is one of the important factors for choosing the suitable stem. We have been applied cemented collarless polished tapered (CPT) stem to the patients with small femur. Radiographic evaluation was performed to access the clinical feature of the stem in early stage of the follow-up. METHODS One hundred total hip arthroplasties with CPT system were performed between October 2004 to February 2006. This study focused on the 53 cases to whom size 1 or smaller sized stem were implanted, and its post-operative period was 41 months (30-46 months). Morphologic classification of preoperative proximal femur, stem alignment, thickness of the cement mantle, cementing technique, subsidence of the stem, improvement in the bone-cement interface, and stress shielding were assessed. RESULTS The size of the inserted stem was X-SMALL in one case, SMALL in two cases, SIZE 0 in 12 cases, and SIZE 1 in 38 cases. Canal shape of proximal femur was stovepipe type in five cases, normal type in 43 cases, and champagne-flute type in five cases. There was no subsidence in eight cases. 44 stems subsided within 1 mm, one stem subsided 1 to 2 mm, and no stem subsided over 2 mm. In 39 of 45 cases, subsidence was appeared within six months after operation. Marked progressive and excessive subsidence was not seen after the two years of follow-up. CONCLUSIONS Short term radiographic results of THA with CPT stem to small femur were satisfactory with less unfavorable radiographic findings, which imply contribution to longer survivorship of the stem.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The influence of cement thickness on stem subsidence and cement creep in a collarless polished tapered stem

OBJECTIVES Favourable results for collarless polished tapered stems have been reported, and cement creep due to taper slip may be a contributing factor. However, the ideal cement thickness around polished stems remains unknown. We investigated the influence of cement thickness on stem subsidence and cement creep. METHODS We cemented six collarless polished tapered (CPT) stems (two stems each ...

متن کامل

Collarless polished tapered stem: clinical and radiological results at a minimum of ten years' follow-up.

We retrospectively reviewed 175 patients (191 hips) who had undergone primary cemented total hip replacement between November 1992 and November 1995 using a collarless polished double-tapered femoral component after a minimum of ten years (mean 11.08; 10 to 12.8). All stems were implanted using contemporary cementing techniques with a distal cement restrictor, pressurised lavage, retrograde cem...

متن کامل

Femoral impaction bone allografting with an Exeter cemented collarless, polished, tapered stem in revision hip replacement: a mean follow-up of 10.5 years.

Femoral impaction bone allografting has been developed as a means of restoring bone stock in revision total hip replacement. We report the results of 75 consecutive patients (75 hips) with a mean age of 68 years (35 to 87) who underwent impaction grafting using the Exeter collarless, polished, tapered femoral stem between 1992 and 1998. The mean follow-up period was 10.5 years (6.3 to 14.1). Th...

متن کامل

Substantially higher prevalence of postoperative peri­prosthetic fractures in octogenarians with hip fractures operated with a cemented, polished tapered stem rather than an anatomic stem

Background and purpose - Recent studies have demonstrated a high incidence of postoperative periprosthetic femoral fracture (PPF) in elderly patients treated with 2 commonly used cemented, polished tapered stems. We compared the prevalence and incidence rate of PPF in a consecutive cohort of octagenerians with femoral neck fractures (FNFs) treated with either a collarless, polished tapered (CPT...

متن کامل

Randomised controlled trial comparing early migration of two collarless polished cemented stems using radiostereometric analysis.

This was a safety study where the hypothesis was that the newer-design CPCS femoral stem would demonstrate similar early clinical results and micromovement to the well-established Exeter stem. Both are collarless, tapered, polished cemented stems, the only difference being a slight lateral to medial taper with the CPCS stem. A total of 34 patients were enrolled in a single-blinded randomised co...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2010