How does CT image noise affect 3D deformable image registration for image-guided radiotherapy planning?
نویسندگان
چکیده
PURPOSE To measure the sensitivity of deformable image registration to image noise. Deformable image registration can be used to map organ contours and other treatment planning data from one CT to another. These CT studies can be acquired with either conventional fan-beam CT systems or more novel cone-beam CT techniques. However, cone-beam CT images can have higher noise levels than fan-beam CT, which might reduce registration accuracy. We have investigated the effect of image quality differences on the deformable registration of fan-beam CTs and CTs with simulated cone-beam noise. METHOD Our study used three CT studies for each of five prostate patients. Each CT was contoured by three experienced radiation oncologists. For each patient, one CT was designated the source image and the other two were target images. A deformable image registration process was used to register each source CT to each target CT and then transfer the manually drawn treatment planning contours from the source CT to the target CTs. The accuracy of the automatically transferred contours (and thus of the deformable registration process) was assessed by comparing them to the manual contours on the target CTs, with the differences evaluated with respect to interobserver variability in the manual contours. Then each of the target CTs was modified to include increased noise characteristic of cone-beam CT and the tests were repeated. Changes in registration accuracy due to increased noise were detected by monitoring changes in the automatically transferred contours. RESULTS We found that the additional noise caused no significant loss of registration accuracy at magnitudes that exceeded what would normally be found in an actual cone-beam CT. SUMMARY We conclude that noise levels in cone-beam CTs that might reduce manual contouring accuracy do not reduce image registration and automatic contouring accuracy.
منابع مشابه
A Study on Robustness of Various Deformable Image Registration Algorithms on Image Reconstruction Using 4DCT Thoracic Images
Background: Medical image interpolation is recently introduced as a helpful tool to obtain further information via initial available images taken by tomography systems. To do this, deformable image registration algorithms are mainly utilized to perform image interpolation using tomography images.Materials and Methods: In this work, 4DCT thoracic images of five real patients provided by DI...
متن کاملEvaluation of deformable image registration in HDR gynecological brachytherapy
Introduction: In brachytherapy, as in external radiotherapy, image-guidance plays an important role. For GYN treatments it is standard to acquire at least CT images and preferably MR images prior to each treatment and to calculate the dose of the day on each set of images. Then, the dose to the target and to the organs at risk (OAR) is calculated with worst case scenario from I...
متن کاملFour-dimensional radiotherapy planning for DMLC-based respiratory motion tracking.
Four-dimensional (4D) radiotherapy is the explicit inclusion of the temporal changes in anatomy during the imaging, planning, and delivery of radiotherapy. Temporal anatomic changes can occur for many reasons, though the focus of the current investigation is respiration motion for lung tumors. The aim of this study was to develop 4D radiotherapy treatment-planning methodology for DMLC-based res...
متن کاملRegistration of 3D U/S and CT images of the Prostate
Radiotherapy is a rapidly growing cancer treatment technique. In brachytherapy – one radiotherapy treatment technique – preand post-planning is usually carried out using CT imaging. As CT scanners cannot easily be moved from one operation room to an other and as CT does not have real-time imaging capability, alternative imaging modalities are needed to realize the vision of image guided surgery...
متن کاملQuantitative evaluation of a cone‐beam computed tomography–planning computed tomography deformable image registration method for adaptive radiation therapy
Deformable (non-rigid) registration is an essential tool in both adaptive radiation therapy and image-guided radiation therapy to account for soft-tissue changes during the course of treatment. The evaluation method most commonly used to assess the accuracy of deformable image registration is qualitative human evaluation. Here,we propose a method for systematically measuring the accuracy of an ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical physics
دوره 35 3 شماره
صفحات -
تاریخ انتشار 2008