The Cement-Bone Interface: A Comparative Experimental and Finite Element Study
ثبت نشده
چکیده
INTRODUCTION: Cement augmentation techniques, such as vertebroplasty, are increasingly being used in the treatment of bony fractures. The rise of such procedures, along with the continued use of cement in total joint replacement, have led to increased interest in the behavior of the bone-cement interface. This region is critical in the performance of joint replacement devices and the load transfer through the spinal segment after vertebroplasty. In previous finite element (FE) studies of joint replacement, the bonecement interface has been represented in a simplified form by the properties of the bone and pure bulk cement respectively. The stemcement-bone interface has been modeled as either perfectly bonded or perfectly un-bonded, and the actual interdigitated bone-cement interface has not been fully represented. In previous studies of vertebroplasty, the augmentation region has also often been represented as pure cement, but a recent study has shown this to lead to a large overestimation in the predicted stiffness of the augmented vertebra [1]. The aim of this study was to compare different methodologies for representing the cement-bone interface using subject-specific models of a trabecular-like foam material augmented with cement. Direct comparisons were made between the model predictions and corresponding experimental tests. The effects on the apparent elastic modulus and the stress due to the relative properties of the cement and foam were also investigated. METHODS: Three sets of six specimens (24 mm diameter, 19 mm height) were cut from an open cell polyurethane foam (Sawbone, Sweden). The first set were not augmented, the second were fully augmented with cement and the third were partially augmented by injecting cement into the centre of the specimen. The cement used in all cases was Cranioplastic (Type 1Slow set, Codman, UK). All specimens were scanned using micro-computed tomography (Scanco μCT80, Switzerland). The specimens were then press-fitted between steel endcaps and tested under axial compression. Based on a previous convergence study [2], finite element (FE) models were built with a maximum element size of 1.5 mm using the μCT image grey-scale data. From the first two sets, factors converting the grey-scale to elastic modulus for each element of the pure sawbone and the cement-sawbone composite were determined by comparison with the compression tests. For the final set, FE models with the same mesh density were generated by three different methods. Method I: both sawbone and cement regions were assigned single homogenous properties; Method II: the elements in the sawbone region were assigned element-specific properties based on the image grey-scale, whilst the cement region was defined with a single homogenous property; Method III: elements in both the sawbone and cement regions were assigned element-specific properties based on the image greyscale using the factors determined from the first two sets. For both Method I and II, different properties of the cement region were defined and compared. Firstly, the properties of the cement region were defined as the same as those of pure cement (2500 MPa), as has been used previously [3]. Secondly an average elastic modulus was defined based on the average greyscale value and the selected conversion factor (giving a value of 345 MPa). To examine the relative effects of the difference in the elastic modulus of the cement and bone, two groups of models were built based on the homogenous models in Methods I. In these groups, the elastic modulus of the sawbone region and cement region were respectively increased to twice their original values. Both the predicted specimen stiffness and maximum von Mises stress were compared with the homogenous models. RESULTS: For the partially cemented computational models, the comparison between the predicted stiffness and that of the experimental values is shown in Figure 1 and the average absolute errors in Table 1. Method I I II II III
منابع مشابه
Simulation of Cement Augmentation at Different Scales: A Combined Experimental and Finite Element Study
Whilst specimen-specific finite element (FE) models of bone have shown good agreement with experimental results, the representation of cement-augmented bone for orthopaedic applications remains a challenge. In previous studies, the bone-cement interface has been represented in simplified forms using continuum level models, but this has been shown to lead to large overestimations in the predicte...
متن کاملMixed-mode loading of the cement-bone interface: a finite element study.
While including the cement-bone interface of complete cemented hip reconstructions is crucial to correctly capture their response, its modelling is often overly simplified. In this study, the mechanical mixed-mode response of the cement-bone interface is investigated, taking into account the effects of the well-defined microstructure that characterises the interface. Computed tomography-based p...
متن کاملInterface micromechanics of transverse sections from retrieved cemented hip reconstructions: an experimental and finite element comparison
In finite element analysis (FEA) models of cemented hip reconstructions, it is crucial to include the cement-bone interface mechanics. Recently, a micromechanical cohesive model was generated which reproduces the behavior of the cement-bone interface. The goal was to investigate whether this cohesive model was directly applicable on a macro level. From transverse sections of retrieved cemented ...
متن کاملThe axisymmetric computational study of a femoral component to analysis the effect of titanium alloy and diameter variation.
This work presents a numerical approach in order to predict the influence of implant material stiffness in a femoral component design when submitted in compression. The implant success depends on the transferred load to the neighboring bone. The finite element method can be used to analysis the stress and strain distribution in the femoral component allowing to improve the implant selection. Fo...
متن کاملCement-Implant Interface Fracture Failure by Crack Initiation Due to Interface Cavity Stress Concentration
Nowadays total joint replacements are widely used in the world, so in average 800,000 joint surgeries are done yearly only in Europe and North America. However implant loosening is and remains as the major issue of all implant failures and therefore causes revision surgery procedures. Studies and experiments have identified poor fixation of implants most likely is the main cause of long term im...
متن کاملBiomechanical effects of morphological variations of the cortical wall at the bone-cement interface
BACKGROUND The integrity of bone-cement interface is very important for the stabilization and long-term sustain of cemented prosthesis. Variations in the bone-cement interface morphology may affect the mechanical response of the shape-closed interlock. METHODS Self-developed new reamer was used to process fresh pig reamed femoral canal, creating cortical grooves in the canal wall of experimen...
متن کامل