Noninvasive monitoring of PaCO2 during one-lung ventilation and minimal access surgery in adults: End-tidal versus transcutaneous techniques
نویسندگان
چکیده
BACKGROUND Previous studies have suggested that end-tidal CO(2) (ET-CO(2)) may be inaccurate during one-lung ventilation (OLV). This study was performed to compare the accuracy of the noninvasive monitoring of PCO(2) using transcutaneous CO(2) (TC-CO(2)) with ET-CO(2) in patients undergoing video-assisted thoracoscopic surgery (VATS) during OLV. MATERIALS AND METHODS In adult patients undergoing thoracoscopic surgical procedures, PCO(2) was simultaneously measured with TC-CO(2) and ET-CO(2) devices and compared with PaCO(2). RESULTS The cohort for the study included 15 patients ranging in age from 19 to 71 years and in weight from 76 to 126 kg. During TLV, the difference between the TC-CO(2) and the PaCO(2) was 3.0 +/- 1.8 mmHg and the difference between the ET-CO(2) and PaCO(2) was 6.2 +/- 4.7 mmHg (P=0.02). Linear regression analysis of TC-CO2 vs. PaCO(2) resulted in an r(2) = 0.6280 and a slope = 0.7650 +/- 0.1428, while linear regression analysis of ET-CO(2)vs. PaCO(2) resulted in an r(2) = 0.05528 and a slope = 0.1986 +/- 0.1883. During OLV, the difference between the TC-CO(2) and PaCO(2) was 3.5 +/- 1.7 mmHg and the ET-CO(2) to PaCO(2) difference was 9.6 +/- 3.6 mmHg (P=0.03 vs. ET-CO(2) to PaCO(2) difference during TLV; and P<0.0001 vs. TC-CO(2) to PaCO(2) difference during OLV). In 13 of the 15 patients, the TC-CO(2) value was closer to the actual PaCO(2) than the ET-CO(2) value (P =0.0001). Linear regression analysis of TC-CO(2)vs. PaCO(2) resulted in an r(2) = 0.7827 and a slope = 0.8142 +/- 0.0.07965, while linear regression analysis of ET-CO(2)vs. PaCO(2) resulted in an r(2) = 0.2989 and a slope = 0.3026 +/- 0.08605. CONCLUSIONS During OLV, TC-CO(2) monitoring provides a better estimate of PaCO(2) than ET-CO2 in patients undergoing VATS.
منابع مشابه
Noninvasive Measurement of Carbon Dioxide during One-Lung Ventilation with Low Tidal Volume for Two Hours: End-Tidal versus Transcutaneous Techniques
BACKGROUND There may be significant difference between measurement of end-tidal carbon dioxide partial pressure (PetCO2) and arterial carbon dioxide partial pressure (PaCO2) during one-lung ventilation with low tidal volume for thoracic surgeries. Transcutaneous carbon dioxide partial pressure (PtcCO2) monitoring can be used continuously to evaluate PaCO2 in a noninvasive fashion. In this study...
متن کاملTranscutaneous PCO2 monitoring during laparoscopic cholecystectomy in pregnancy.
PURPOSE Respiratory acidosis during carbon dioxide (CO2) insufflation has been suggested as a cause of spontaneous abortion and preterm labour following laparoscopic cholecystectomy during pregnancy. Capnography may not be adequate as a guide to adjust pulmonary ventilation during laparoscopic surgery and hence arterial carbon dioxide (PaCO2) monitoring has been recommended. We report the feasi...
متن کاملNoninvasive carbon dioxide monitoring in a porcine model of acute lung injury due to smoke inhalation and burns.
In critically ill intubated patients, assessment of adequacy of ventilation relies on measuring partial pressure of arterial carbon dioxide (PaCO2), which requires invasive arterial blood gas analysis. Alternative noninvasive technologies include transcutaneous CO2 (tPCO2) and end-tidal CO2 (EtCO2) monitoring. We evaluated accuracy of tPCO2 and EtCO2 monitoring in a porcine model of acute lung ...
متن کاملMonitoring of end tidal carbon dioxide and transcutaneous carbon dioxide during neonatal transport.
OBJECTIVE To assess the accuracy of measurements of end tidal carbon dioxide (CO2) during neonatal transport compared with arterial and transcutaneous measurements. DESIGN Paired end tidal and transcutaneous CO2 recordings were taken frequently during road transport of 21 ventilated neonates. The first paired CO2 values were compared with an arterial blood gas. The differences between arteria...
متن کاملNoninvasive monitoring of oxygen and carbon dioxide.
New technologies for the noninvasive assessment of oxygen and carbon dioxide are transforming clinical practice. Transcutaneous monitoring of PO2 (PtcO2) and PCO2 (PtCO2) provides an approximation of PaO2 and PaCO2 values in hemodynamically normal individuals, but both PtcO2 and PtcCO2 diverge from the corresponding arterial values when cardiac output is reduced, even in the absence of hypotens...
متن کامل