Efficacy and efficiency of a new involutional ptosis correction procedure compared to a traditional aponeurotic approach.

نویسندگان

  • Bartley R Frueh
  • David C Musch
  • Hector McDonald
چکیده

PURPOSE This was a retrospective study to compare the efficacy and efficiency of a new small anterior incision, minimal dissection ptosis procedure with that of a traditional anterior aponeurotic approach for the correction of aponeurotic ptosis. METHODS The results of a chart and photograph review of 36 patients with 49 ptotic eyelids who had ptosis correction by a small-incision, minimal dissection procedure were compared with those of 36 patients with 49 ptotic eyelids who had ptosis correction by a traditional aponeurotic approach. RESULTS The successful correction of the eyelid height and the rate of recommendation for reoperation were not significantly different for the 49 lids corrected in each arm of the study. The incidence of attaining good eyelid contour was significantly better in the small-incision group, where 41 (97.6%) of 42 lids evaluated by photographs had good contour compared with 29 (78.4%) of 37 lids in the traditional group. Operating time per lid was significantly less for the small-incision, minimal dissection group, 25.3 +/- 13.0 minutes (range, 13 to 68 minutes), compared with 55.4 +/- 16.6 minutes (range, 35 to 119) for the traditional group. CONCLUSIONS Compared with the traditional aponeurotic approach, the new small-incision, minimal dissection technique for ptosis correction is equally efficacious in correcting eyelid height, superior in producing desirable eyelid contour, and much quicker to perform.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Posterior approach white line advancement ptosis repair: the evolving posterior approach to ptosis surgery.

INTRODUCTION We describe a surgical technique for ptosis correction in moderate to good levator function involving advancement of the levator aponeurosis via a transconjunctival posterior approach without resection of Müller's muscle. We present our experience of and the results from this method, and review the evolution of posterior approach ptosis surgery. PURPOSE To assess the efficacy and...

متن کامل

External levator advancement vs Müller's muscle-conjunctival resection for correction of upper eyelid involutional ptosis.

PURPOSE To compare external levator advancement and Müller's muscle-conjunctival resection (conjunctivomullerectomy, or CJM) for correction of upper eyelid involutional ptosis. DESIGN Retrospective, nonrandomized, comparative interventional case series. METHODS Review of medical records of 159 patients (272 surgical procedures) who underwent external levator advancement or CJM was performed...

متن کامل

Combined Subbrow Excision with Upper Blepharoplasty Using a Tadpole Shaped Excision for Blepharochalasis

In efforts to solve blepharochalasis, the problem of droopy eyelids that happens as people age, various surgical methods have been developed and disclosed over the years. Among them, classical upper blepharoplasty, the most fundamental procedure, involves excision of redundant eyelid skin in the upper palpebrae [1-4]. This operation utilizes an approach through the lid crease line of the upper ...

متن کامل

The Efficacy of the Combined Procedure in Involutional Entropion Surgery: A Comparative Study

PURPOSE To evaluate the efficacy of the combined procedure in the management of involutional entropion. METHODS In this study, we reviewed 45 eyes of 36 patients who underwent the combined procedure (lateral tarsal strip, retractor tightening, and everting sutures) for the management of involutional lower eyelid entropion and compared the results with 31 eyes of 25 patients who underwent the ...

متن کامل

A New Approach for Reactive Power Control of Single Phase Transformerless Inverter to Modify Power Quality in Stand Alone Micro-Grids with Current Leakage Elimination

Nowadays there has been an increasing interest in transformerless inverter for grid-connected photovoltaic (PV) system due to low cost, high efficiency and light weight. One of the reasons describe the grid behavior is capability of reactive power control by inverter. According to the standard VDE-AR-N 4105, grid-tied PV inverter of power rating below 3.68KVA, should attain power factor (PF) fr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Transactions of the American Ophthalmological Society

دوره 102  شماره 

صفحات  -

تاریخ انتشار 2004