Removal of Residual Motion Artifacts in fMRI using Constrained Independent Component Analysis

نویسندگان

  • K. K. Pandey
  • D. C. Noll
چکیده

Introduction: Image registration of fMRI data only corrects for bulk movements while leaving secondary artifacts such as, spin history effects, motion induced dynamic field inhomogeneity changes, and interpolation errors untouched. Secondary artifacts increase variability in time-series and reduce sensitivity of activation detection. Methods such as the use estimated motion parameters as “Nuisance Explanatory Variables” (NEV) in a General Linear Model (GLM), [GLM+NEV] [1], or use of Independent Component Analysis (ICA) [2,3] to isolate and remove motion related components are commonly used to remove residual motion artifacts after image registration. Use of ICA, while very effective, is a two stage process involving, first, isolation and subsequent identification of motion components before removing them. The identification step can be tedious and time consuming as one has to manually inspect or use a similarity measure to identify/isolate components that are due to motion. However, ICA does have an advantage over use of motion parameters as NEVs in GLM. ICA is able to better isolate sources or components that are related to motion in a possibly non-linear and unpredictable fashion namely, interactions of susceptibility induced field inhomogeneity with motion, interpolation artifacts and other structured noises [2,3,4]. Thus, it is potentially a more complete method of correcting for residual motion artifacts compared to use of GLM+NEV. In this study, we used temporally constrained ICA (cICA) [5,6] to combine isolation and identification of residual motion artifact components into a single step using estimated motion parameters as references for the cICA algorithm. We also explored whether use of cICA with motion parameters as references improved quality and completeness of removal of residual motion artifacts in BOLD fMRI. Methods: Separate scans, each 200 seconds long, were acquired while four volunteers performed a visual motor task inside the scanner. Each scan consisted of five 40-second cycles of alternating task and control periods. Each volunteer was instructed to intentionally move their head during the scans. These motion corrupted images in the time series were then realigned using MCFLIRT utility of FSL [7]. Statistical parametric analysis was carried out on the realigned images in four different ways. i) GLM: Activation parameters were estimated using a GLM as implemented in FEAT utility of FSL. ii) cICA: Six estimated motion parameters were used as references for cICA algorithm to isolate components most correlated to motion. These components were then removed and the rest combined to obtain a time series of images with reduced residual motion artifacts. iii) GLM+NEV: Similar to “GLM” method however estimated motion parameters were included as NEVs in the GLM design matrix. iv) cICA+NEV: Same as in cICA but, motion parameters were included as NEV in the GLM matrix for estimation of statistical parameters. A z-threshold of > 3.5 was used to identify active pixels. Active pixels in the brain were aggregated into a histogram with ten bins over a range of zscores, 3.5 up to max z-score value. Number of active pixels at each bin was added cumulatively to generate a graph that showed the incremental number of active pixels at each bin (z-score value) and the total number of active pixels detected thus far – the final data point represents the sum of all active pixels. These cumulative graphs were compared across the four analysis methods (see figure 1). Results: FIGURE – 1 FIGURE 2

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Spatiotemporal Signal Space Projection Method for Artifact Reduction in Simultaneous EEG-fMRI Acquisitions

Introduction When acquiring simultaneous EEG-fMRI data, there can be significant artifacts in the EEG data due to MR gradients, cardiac pulsations, and other interference sources from outside the brain. Although some of these artifacts can be greatly reduced using template based subtractions [1,2], residual artifacts typically persist. The residual artifacts can be removed with component-based ...

متن کامل

Independent component analysis and artifact removal in human calf muscle functional MRI

Introduction: Alterations in tissue perfusion occur in a variety of disorders such as cardiovascular disease [1]. Tissue reperfusion after ischemia involves two mechanisms: a strong increase in tissue perfusion and a change in oxygenation levels, both of which contribute to the contrast in blood oxygenation level-dependent functional magnetic resonance imaging (fMRI) [2]. Echo planar imaging (E...

متن کامل

Feature selection using genetic algorithm for classification of schizophrenia using fMRI data

In this paper we propose a new method for classification of subjects into schizophrenia and control groups using functional magnetic resonance imaging (fMRI) data. In the preprocessing step, the number of fMRI time points is reduced using principal component analysis (PCA). Then, independent component analysis (ICA) is used for further data analysis. It estimates independent components (ICs) of...

متن کامل

Complete artifact removal for EEG recorded during continuous fMRI using independent component analysis.

The simultaneous recording of EEG and fMRI is a promising method for combining the electrophysiological and hemodynamic information on cerebral dynamics. However, EEG recordings performed in the MRI scanner are contaminated by imaging, ballistocardiographic (BCG) and ocular artifacts. A number of processing techniques for the cancellation of fMRI environment disturbances exist: the most popular...

متن کامل

Quantification of motion-related artifacts in simulated FMRI data using ICA

I. Drobnjak, C. F. Beckmann, M. Jenkinson Oxford Centre for FMRI of the Brain, University of Oxford, Oxford, United Kingdom, Computing Laboratory, University of Oxford, Oxford, United Kingdom Introduction: FMRI data contain many motion-related artefacts which can limit its usefulness. Many approaches exist to correct for rigid-body motion effects but they struggle to do so in cases when motion ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008