Interchangeability between Placido disc and Scheimpflug system: quantitative and qualitative analysis.

نویسندگان

  • Vinícius Silbiger de Stefano
  • Luiz Alberto Soares Melo Junior
  • Felipe Mallmann
  • Paulo Schor
چکیده

PURPOSE Many systems try to replace Placido disc-based topographers, such as those based in Scheimpflug principles. The purpose of this study is to check if they are interchangeable. METHODS Quantitative analysis evaluated data obtained from EyeSys and Pentacam, i.e. simulated keratometric values, in addition to flattest and steepest keratometric values. Sixty-three maps from each device (EyeSys scale=0.5 D; Pentacam scale= 0.25 D) were used for the comparison. Qualitative analysis selected 10 EyeSys and 15 Pentacam topographies used in the quantitative evaluation. Aspheric, keratoconus suspects (KS) and established keratoconus corneas were included. Four groups (children [CH], non-physicians adults [AD], residents in ophthalmology [OP] and refractive surgeons [RS]) were asked to match the topographies belonging to the same eye. RESULTS Analysis showed that the parameters are correlated; however they are not clinically similar. In the qualitative analysis, the percent of correct matches increased when KS was removed. CH group was statistically different from every group in these comparisons. When only KS was considered, CH vs. OP, CH vs. RS and AD vs. RS remained statistically different. AD vs. OP showed no relevant difference in any comparison. CONCLUSIONS The systems are not fully interchangeable, yet they are correlated. Practitioners who are adapting to Pentacam should use the 0.25 D scale maps and transform formulas that use EyeSys parameters. Only with persistent training may the topographies be properly matched; KS corneas are more difficult to be correctly paired.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Corneal thickness, curvature, and elevation readings in normal corneas: combined Placido-Scheimpflug system versus combined Placido-scanning-slit system.

PURPOSE To evaluate agreement in central corneal thickness (CCT), keratometry, and anterior and posterior elevation map measurements in normal corneas between a combined Placido-Scheimpflug system and a combined Placido-scanning-slit elevation topography system. SETTING Department of Cataract & Refractive Surgery, Rothschild Foundation, Paris, France. DESIGN Evaluation of diagnostic test or...

متن کامل

Forme Fruste Keratoconus Imaging and Validation via Novel Multi-Spot Reflection Topography

BACKGROUND/AIMS This case report aims to evaluate safety, efficacy and applicability of anterior surface imaging in a patient with forme fruste keratoconus (FFKC) based on a novel multi-spot, multicolor light-emitting-diode (LED) tear film-reflection imaging technology. CASE DESCRIPTION A 45-year-old male patient, clinically diagnosed with FFKC, with highly asymmetric manifestation between hi...

متن کامل

3D refraction correction and extraction of clinical parameters from spectral domain optical coherence tomography of the cornea.

Capable of three-dimensional imaging of the cornea with micrometer-scale resolution, spectral domain-optical coherence tomography (SDOCT) offers potential advantages over Placido ring and Scheimpflug photography based systems for accurate extraction of quantitative keratometric parameters. In this work, an SDOCT scanning protocol and motion correction algorithm were implemented to minimize the ...

متن کامل

Assessment of anterior segment parameters in morbid obesity

Abstract. – OBJECTIVE: To investigate the measurement of anterior segment parameters using Sirius Scheimpflug-Placido topographer, Lenstar optical low coherence reflectometry (OLCR), and noncontact specular microscopy (SM) in morbidly obese and nonobese subjects. PATIENTS AND METHODS: Twenty-eight morbidly obese subjects (BMI ≥ 40; Group 1) and 28 agesex-matched healthy nonobese subjects (BMI 1...

متن کامل

Comparison of Placido disc and Scheimpflug image-derived topography-guided excimer laser surface normalization combined with higher fluence CXL: the Athens Protocol, in progressive keratoconus

BACKGROUND The purpose of this study was to compare the safety and efficacy of two alternative corneal topography data sources used in topography-guided excimer laser normalization, combined with corneal collagen cross-linking in the management of keratoconus using the Athens protocol, ie, a Placido disc imaging device and a Scheimpflug imaging device. METHODS A total of 181 consecutive patie...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Arquivos brasileiros de oftalmologia

دوره 73 4  شماره 

صفحات  -

تاریخ انتشار 2010