Evaluating formability of LCP plate for sacral fractures with one step inverse forming finite element analysis.

نویسندگان

  • Xiaoda Li
  • Xiangkui Zhang
  • Ping Hu
  • Weijie Liu
  • Guozhe Shen
  • Xianghui Zhan
چکیده

The locking compression plate fixation treatment for the unstable sacral fractures is simple and effective, with less trauma and complications. Some locking compression plate parts have been made of high-strength Plate manufactured by hot stamping process since the demand for lightweight biomedical materials. Finite Element (FE) method of One-Step inverse forming based on deformation theory is the tool to evaluate the formability of locking compression plate panel quickly in initial design for reducing costs and development cycle of Plate. But current one-step inverse forming methods are all suitable for cold stamping, not hot-stamping. This paper proposed one-step inverse forming method and workflow for hot-stamping of locking compression Plate. And the B pillar of a sacral bone was simulated and its computing result was compared with experimental value. The result shows that the proposed method in this paper can quickly evaluate high temperature formability of high-strength Plate. And the method is proposed to be used in initial design.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Parallel analysis of finite element model controlled trial and retrospective case control study on percutaneous internal fixation for vertical sacral fractures

BACKGROUND Although percutaneous posterior-ring tension-band metallic plate and percutaneous iliosacral screws are used to fix unstable posterior pelvic ring fractures, the biomechanical stability and compatibility of both internal fixation techniques for the treatment of Denis I, II and III type vertical sacral fractures remain unclear. METHODS Using CT and MR images of the second generation...

متن کامل

Investigation on Formability of Tailor-Welded Blanks in Incremental Forming

Steel laser tailor-welded blanks (TWBs) are produced by end-to-end joining of base sheets using different welding methods. In this article, the formability of laser TWBs of St12 and St14 with thicknesses of 1 mm and 1.5 in single point incremental forming process were experimentally and numerically investigated. First, the forming limit wall angle was experimentally determined for each of the b...

متن کامل

Biomechanical Property of a Newly Designed Assembly Locking Compression Plate: Three-Dimensional Finite Element Analysis

In this study, we developed and validated a refined three-dimensional finite element model of middle femoral comminuted fracture to compare the biomechanical stability after two kinds of plate fixation: a newly designed assembly locking compression plate (NALCP) and a locking compression plate (LCP). CT data of a male volunteer was converted to middle femoral comminuted fracture finite element ...

متن کامل

Analysis of deep drawing process to predict the forming severity considering inverse finite element and extended strain-based forming limit diagram

An enhanced unfolding Inverse Finite Element Method (IFEM) has been used together with an extended strain-based forming limit diagram (EFLD) to develop a fast and reliable approach to predict the feasibility of the deep drawing process of a part and determining where the failure or defects can occur. In the developed unfolding IFEM, the meshed part is properly fold out on the flat sheet and tre...

متن کامل

Investigation on the Ultrasonic Tube Hydroforming in the Bulging Process Using Finite Element Method

In ultrasonic tube hydroforming, the tube is hydro formed while the ultrasonic vibration is applied to the die. Prior studies provide experimental proof that ultrasonic tube hydroforming reduces corner radius, improves lubrication and uniform thickness. Use of ultrasonic vibration can decrease friction at the tube-die interface. Few attempts have been made to analyze the wire drawing while the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Bio-medical materials and engineering

دوره 26 Suppl 1  شماره 

صفحات  -

تاریخ انتشار 2015