When should Doppler-determined valve area be better than the Gorlin formula?: Variation in hydraulic constants in low flow states.
نویسندگان
چکیده
In low flow states, underestimation errors occur when the Gorlin formula is used to calculate valve area. A model of valvular stenosis designed to examine changes in the hydraulic discharge coefficient (Cd) and coefficient of orifice contraction (Cc) may explain these errors. Unsteady flow was examined in a pulsatile pump model and in a dog model. Valve areas were calculated from pressure and flow data using: a modified form of the Gorlin formula (assuming constant values for Cd and Cc) and a corrected formula (with values of Cd and Cc obtained from steady state data). Valve area was also calculated using the continuity equation with velocity and flow data (constant Cc). Flow velocities were measured using a newly designed ultrasound Doppler catheter capable of resolving flow velocities of up to 5.5 m/s. Both the corrected formula and continuity equation were highly predictive of actual valve area (r = 0.99, slope or M = 0.96 and r = 0.99, M = 1.06, respectively). The modified Gorlin equation was less accurate and tended to underestimate valve areas (r = 0.87, M = 0.83). This underestimation was most notable at low rates of flow (Gorlin: r = 0.94, M = 0.53; continuity: r = 0.93, M = 0.81 and r = 0.94, M = 0.89, respectively) more accurately than the modified Gorlin formula (r = 0.69, M = 0.49). In patients with low cardiac output, hemodynamic formulas, such as the Gorlin formula, which assume a constant value for the hydraulic discharge coefficient (Cd), may be less accurate than formulas using either a corrected value of Cd or Doppler-determined flow velocity and mean systolic flow.
منابع مشابه
Doppler assessment of prosthetic valve orifice area. An in vitro study.
BACKGROUND Although Doppler echocardiography has been shown to be accurate in assessing stenotic orifice areas in native valves, its accuracy in evaluating the prosthetic valve orifice area remains undetermined. METHODS AND RESULTS Doppler-estimated valve areas were studied for their agreement with catheter-derived Gorlin effective orifice areas and their flow dependence in five sizes (19/20-...
متن کاملDoppler Assessment of Prosthetic Valve Orifice Area
Background. Although Doppler echocardiography has been shown to be accurate in assessing stenotic orifice areas in native valves, its accuracy in evaluating the prosthetic valve orifice area remains undetermined. Methods and Results. Doppler-estimated valve areas were studied for their agreement with catheterderived Gorlin effective orifice areas and their flow dependence in five sizes (19/20-2...
متن کاملComparison of Doppler echocardiographic methods with heart catheterisation in assessing aortic valve area in 100 patients with aortic stenosis.
OBJECTIVE To examine the practicability and accuracy of Doppler echocardiographic methods in determining aortic valve area. METHODS Aortic valve areas determined by three methods using Doppler echocardiography (applying the continuity equation and the modified Gorlin formula using data from Doppler echocardiography and right heart catheterisation) were compared with values obtained by heart c...
متن کاملSimultaneous Determination of Aortic Valve Area by the Gorlin Formula and by Transesophageal Echocardiography Under Different Transvalvular Flow Conditions
Objectives. The purpose of this study was to determine the impact of changes in flow on aortic valve area (AVA) as measured by the Gorlin formula and transesophageal echocardiographic (TEE) planimetry. Background. The meaning of flow-related changes in AVA calculations using the Gorlin formula in patients with aortic stenosis remains controversial. It has been suggested that flow dependence of ...
متن کاملDependence of Gorlin formula and continuity equation valve areas on transvalvular volume flow rate in valvular aortic stenosis.
BACKGROUND Valve areas derived by the Gorlin formula have been observed to vary with transvalvular volume flow rate. Continuity equation valve areas calculated from Doppler-echo data have become a widely used alternate index of stenosis severity, but it is unclear whether continuity equation valve areas also vary with volume flow rate. This study was designed to investigate the effects of chang...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the American College of Cardiology
دوره 9 6 شماره
صفحات -
تاریخ انتشار 1987