Inflammatory mediated chronic anemia in patients supported with a mechanical circulatory assist device.

نویسندگان

  • Christopher N Pierce
  • Douglas F Larson
  • Francisco A Arabia
  • Jack G Copeland
چکیده

It is widely accepted and clinically anticipated that the patient implanted with a mechanical circulatory assist device (MCAD) will develop a state of chronic anemia that will last throughout the duration of MCAD support. Large-scale hemolysis mediated by the high sheer stress transmitted to the erythrocytes (RBCs) from the mechanical action of most MCAD systems is the accustomed mechanism responsible for this anemic status. MCAD patients exhibiting chronic anemia require frequent blood transfusions placing the patients at a high infectious risk to maintain an acceptable hematocrit. It is also acknowledged that the biomaterial interaction of the MCAD with the immune system precipitates a chronic inflammatory state in this patient population. Taken together, we hypothesize that inflammatory mediation of the erythropoiesis pathway at multiple sites-limiting the replacement of lysed RBCs-dictates the extent of chronic anemia in MCAD patients more than mechanical trauma to the blood. Hematological parameters were retrospectively analyzed for 78 patients implanted with a mechanical circulatory assist device for greater than 30 days at the University of Arizona Health Sciences Center between the years 1996 to 2002. Analysis demonstrates that the rate of hemolysis slows after MCAD implantation, marked by a progressively decreasing plasma hemoglobin concentration. In addition, the absolute reticulocyte count, a marker of juvenile RBC production, increases and remains above maximum normal values after MCAD implantation. Furthermore, the mean cell hemoglobin concentration indicates sufficient substrate for RBC development and maturation. However, hematocrit, a conventional marker of anemia, drops and remains below minimum normal value throughout the measured time period. A state of anemia in the MCAD supported patient results initially from the effect of hemolysis associated with the mechanical action of the MCAD, then chronically persists as the result of another undetermined mechanism. Given the state of chronic inflammation in the patient population, immunological activation most likely limits the full production of RBCs to their mature state.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Systemic inflammation in patients with heart failure.

AIMS We hypothesized that chronic heart failure as a model of systemic hypoxia may result in systemic inflammation. The signs of a systemic inflammatory response should disappear after successful mechanical circulatory support using biventricular assist device systems. METHODS AND RESULTS Plasma levels of cytokines (IL-6, IL-8, TNF-alpha) and soluble adhesion molecules (sVCAM, sE-, sL-, sP-Se...

متن کامل

Double lung procurement from a donor supported by a left ventricular assist device.

Over the past several years, the selection criteria for marginal donor lungs have been extended. However, brain-dead patients with implanted mechanical circulatory support systems have not yet been considered as potential organ donors for lung transplantation. Our report presents the first successful procurement and transplantation of donor lungs from a patient supported by a left ventricular a...

متن کامل

Mechanical circulatory support for end-stage heart failure.

Mechanical circulatory assistance has become a frequent therapeutic option for patients with advanced heart failure. For patients with acute cardiogenic shock and impaired organ function, short-term assistance with venoarterial extracorporeal membrane oxygenation is the leading therapeutic option. It enables a "bridge to decision-making" i.e. withdrawal of the device after myocardial recovery o...

متن کامل

Ex-vivo recruitment and x-ray assessment of donor lungs in a challenging retrieval from a donor supported by lvad using the portable normothermic perfusion system: a case report

BACKGROUND Lung transplantation (LTx) is limited by the shortage of suitable donors. To overcome this problem, many programs have begun to use donors with extended criteria (marginal donors). However, brain-dead patients with implanted mechanical circulatory support system have rarely been considered as potential lung donors. This case demonstrates the feasibility of lung transplantations from ...

متن کامل

Quality of life and left ventricular assist device support.

More than 5 million Americans are living with heart failure, with an additional 500 000 cases diagnosed each year.1 Ongoing improvements in patient management will only increase the number of patients surviving to develop severe refractory heart failure (stage D). Approximately 5% to 10% of all heart failure patients are classified as stage D and defined as patients who continue to have symptom...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The journal of extra-corporeal technology

دوره 36 1  شماره 

صفحات  -

تاریخ انتشار 2004