True 3D chemical dosimetry (gels, plastics): Development and clinical role

نویسنده

  • L J Schreiner
چکیده

Since the introduction of volumetric chemical dosimetry with Fricke gel dosimeters in the 1980s, three-dimensional (3D) dosimetry has been a promising technique for the clinic, since it provides a unique methodology for 3D dose measurement of the complex conformal dose distributions achieved by modern techniques such as Intensity Modulated and Volumetric Arc Radiation Therapy. In the last decade, the potential for improved clinical applicability has been advanced by the development of improved 3D dosimeters such as normoxic polymer gel systems, radiochromic plastics (such as PRESAGE) and, recently, newer radiochromic gel dosimeters. Some of these new 3D dosimetry systems were enabled by the availability of optical computed tomography imaging systems for fast dose readout. However, despite its promise, true 3D dosimetry is still not widely practiced in the community. Its use has been confined primarily to select centres of expertise and to specialised quality assurance or commissioning roles where other dosimetry techniques are difficult to implement. In this paper I review some of the current 3D chemical dosimeters available, discuss the requirements for their use and briefly review the roles that these systems can provide to complement the other dose delivery validation approaches available in the clinic. I conclude by describing two roles that may be uniquely served by 3D chemical dosimetry in end-to-end process testing and validation in the complex environment coming into play with the development of Image Guided Adaptive Radiation Therapy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of an Advanced Optical Coherence Tomography System for Radiation Dosimetry

Introduction: According to the literature, optical coherence tomography (OCT) can be used measure radiation absorbed dose. This study was carried out to design a computed tomography system for the calculation of absorbed dose and optimization of dose delivery in radiotherapy using gel dosimeters. Material and Methods: An advanced charge-coupled device based OCT system was developed in laborator...

متن کامل

Electron Beam Dosimetry in Heterogeneous Phantoms Using a MAGIC Normoxic Polymer Gel

Introduction: Nowadays radiosensitive polymer gels are used as a reliable dosimetry tool for verification of 3D dose distributions. Special characteristics of these dosimeters have made them useful for verification of complex dose distributions in clinical situations. The aim of this work was to evaluate the capability of a normoxic polymer gel to determine electron dose distributions in differ...

متن کامل

Improvement of Accuracy in Environmental Dosimetry by TLD Cards Using Three-dimensional Calibration Method

Background: The angular dependency of response for TLD cards may cause deviation from its true value on the results of environmental dosimetry, since TLDs may be exposed to radiation at different angles of incidence from the surrounding area.Objective: A 3D setting of TLD cards has been calibrated isotropically in a standard radiation field to evaluate the improvement of the accuracy of meas...

متن کامل

3D MRI gel dosimetry based on image intensity (A new approach)

Background: Since 1984 MRI gel dosimetry has been introduced as a potential technique for 3D dosimetry. Most of the studies have measured R1 (1/T1) or R2 (1/T2) properties of the gel depending on the gel type. We have studied image intensity change in the Fricke gel by different MRI protocols. Materials and Methods: Gel Dosimeters contain 0.4 mM ferrous sulphate, 1 mM NaCl, 50 mM H2SO4 and 1% b...

متن کامل

Optical Characterization of NIPAM and PAGAT Polymer Gels for Radiation Dosimetry

Introduction The purpose of the current study was to determine optical sensitivity of N-isopropyl acrylamide NIPAM and polyacrylamide gelatin and tetrakis hydroxymethyl phosphoniun chloride (PAGAT) polymer gels for different wavelength of visible light spectrum applied in optical computed tomography method. Materials and Methods NIPAM and PAGAT polymer gels with conventional formulations used f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014