Direct solid-phase enzymoimmunoassay of testosterone in saliva.
نویسندگان
چکیده
This competitive, solid-phase enzymoimmunoassay for testosterone in saliva is carried out on microtiter plates and involves no chromatographic or extraction steps. With an overnight incubation the detection limit of the assay is 230 fg per well (16.1 pmol/L). There was a good correlation (correlation coefficient 0.95) between testosterone concentrations measured with and without prior extraction of the saliva samples. Repeated assay of three control saliva samples containing a range of testosterone concentrations (200-1000 pmol/L) gave within- and between-assay coefficients of variation of 5.5-13.2%. The analytical procedure is simple and closely resembles already published procedures for the determination of progesterone and estrone (with extraction) in saliva. One person can assay 200 samples in 24 h and the assay is suitable for reproductive and sports medical applications, particularly for projects involving serial sampling and yielding large numbers of samples.
منابع مشابه
Solid-phase enzymoimmunoassay of estrone in saliva.
In this solid-phase enzymoimmunoassay for estrone in saliva, microtiter plates are used after extraction of the sample with diethyl ether. No chromatographic step is involved. The detection limit of the assay is 450 fg per well (33 pmol/L). Intra- and interassay coefficients of variation for the assay of low, medium, and high concentrations of estrone in saliva were respectively 4.2, 12.7; 5.2,...
متن کامل[Evaluation of an immunoassay kit to measure free testosterone].
INTRODUCTION AND OBJECTIVES The best indicators to the diagnosis of hypogonadism are free and bioavailable testosterone circulating levels. Free and bioavailable testosterone measurements are complex. However, simple kits for direct measurement of free testosterone by analog immunoassay are available. We examined the utility of an enzymoimmunoassay kit for free testosterone measurement. MATER...
متن کاملRapid, competitive enzymoimmunoassay for albumin in urine.
In this solid-phase competitive enzymoimmunoassay for albumin in human urine, antiserum to human serum albumin labeled with horseradish peroxidase (EC 1.11.1.7) is incubated with solid-phase-bound human serum albumin in the presence of sample or standard. Results obtained correlate well (r = 0.96) with those of an established fluoroimmunoassay. The present assay covers the range 0.9 to 200 mg/L...
متن کاملSolid-phase enzymoimmunoassay for osteocalcin in human serum or plasma, with use of a monoclonal antibody.
In this solid-phase enzymoimmunoassay on microtiter plates for osteocalcin in serum or plasma, we use an osteocalcin-horseradish-peroxidase conjugate and a monoclonal antibody raised against bovine osteocalcin. We thoroughly standardized the assay for measurement of osteocalcin in both serum and plasma, demonstrating independence of sample volume, and determining the analytical recovery and wit...
متن کاملDevelopment and Validation of HPLC Method for Determination of Crocetin, a constituent of Saffron, in Human Serum Samples
Objective(s):The present study reports the development and validation of a sensitive and rapid extraction method beside high performance liquid chromatographic method for the determination of crocetin in human serum. Materials and Methods:The HPLC method was carried out by using a C18 reversed-phase column and a mobile phase composed of methanol/water/acetic acid (85:14.5:0.5 v/v/v) at the flow...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry
دوره 35 10 شماره
صفحات -
تاریخ انتشار 1989