Misalignments always occur in real optical systems. These misalignments do not generate new aberration forms, but they change the aberration field dependence. Two-mirror telescopes have been used in several applications. We analyze a two-mirror telescope configuration that has negligible sensitivity to decenter misalignments. By applying the wave aberration theory for plane-symmetric optical systems it is shown that the asphericity in the secondary mirror, if properly chosen, can compensate for any decenter perturbation allowing third-order coma unchanged across the field of view. For any two-mirror system it is possible to find a configuration in which decenter misalignments do not generate field-uniform coma.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Generic Misalignment Aberration Patterns in Wide-Field Telescopes

Axially symmetric telescopes produce well known “Seidel” off-axis third-order aberration patterns: coma, astigmatism, curvature of field and distortion. When axial symmetry is broken by the small misalignments of optical elements, additional third-order aberration patterns arise: one each for coma, astigmatism and curvature of field and two for distortion. Each of these misalignment patterns is...

متن کامل

The misalignment induced aberrations of TMA telescopes.

The next major space-borne observatory, the James Webb Space Telescope, will be a 6.6M field-biased, obscured, three-mirror anastigmat (TMA). Over the used field of view, the performance of TMA telescopes is dominated by 3(rd) order misalignment aberrations. Here it is shown that two dominant 3(rd) order misalignment aberrations arise for any TMA telescope. One aberration, field constant 3(rd) ...

متن کامل

Third-order coma-free point in two-mirror telescopes by a vector approach.

In this paper, two-mirror telescopes having the secondary mirror decentered and/or tilted are considered. Equations for third-order coma are derived by a vector approach. Coma-free condition to remove misalignment-induced coma was obtained. The coma-free point in two-mirror telescopes is found as a conclusion of our coma-free condition, which is in better agreement with the result solved by Wil...

متن کامل

Using Nodal Aberration Theory to understand the aberrations of multiple unobscured Three Mirror Anastigmatic (TMA) telescopes

The alignment of three mirror anastigmatic (TMA) telescopes has been studied since their invention in the 60s. Recently, Thompson et al. reported that other than the conventional uniform coma over the field caused by misalignment, TMA telescopes display only one other misalignment induced aberration, field-asymmetric, field-linear astigmatism. Currently, an instrument with three TMAs is under d...

متن کامل

Misalignment characteristics of resonators formed by 900 cone and mirror

The stability condition of a resonator formed by a 900 cone and mirror has been derived using ray tracing techniques. The result showed that this type of resonator is relatively insensitive to mirror misalignment. From this basis, the mirror misalignment tolerance was studied experimentally. Output energy and transverse mode characteristics vs. misalignment were measured, and the results show t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Optics express

دوره 21 6  شماره 

صفحات  -

تاریخ انتشار 2013