Percutaneous closure of a modified Blalock-Taussig shunt using an amplatzer vascular plug.

نویسندگان

  • Raúl E Rios-Méndez
  • Ricardo Gamboa
  • Francisco P Mollón
چکیده

Modified Blalock-Taussig shunts are usually clamped during the successive corrective or palliative surgical procedures carried out to treat underlying congenital heart disease, though at times they may be left permeable for a number of reasons. Subsequently, when this is no longer considered necessary and closure is indicated, the method of choice is percutaneous embolization using various coils or other devices. We report on a series of patients in whom this type of shunt was closed successfully via an arterial approach using a new device: the Amplatzer Vascular Plug. In addition to employing a controlled-release system, this type of plug has the advantage that it can be implanted using low-profile catheters. The patients were 1, 4 and 23 years old, respectively, and no complications were reported. The fluoroscopy time was 10, 11 and 9 minutes, respectively, and patients were followed up for 42 months.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Percutaneous closure of Blalock-Taussig shunts using Gianturco coils.

Permeability of a Blalock-Taussig shunt can increase the risk of endocarditis and ventricular overload. Percutaneous embolization of these shunts gives variable results. We report our experience in 10 patients with percutaneous closure of modified Blalock-Taussig shunts using retrograde arterial embolization with Gianturco coils. The patients' median age was 2.8 years, and their median weight w...

متن کامل

Closure of Blalock-Taussig shunts using a new detachable coil device.

Two children underwent interventional closure of a modified Blalock-Taussig shunt using a new detachable coil system (Duct-Occlud). This procedure has advantages over currently available materials to occlude these and other communications between the systemic and pulmonary circulations.

متن کامل

A novel use of an Amplatzer septal occluder.

A 4 year old girl with an underlying diagnosis of atrioventricular discordance, double outlet right ventricle with pulmonary valvar atresia, and subpulmonary ventricular septal defect, was admitted for elective surgery. She had had surgery as a neonate to insert a right 5 mm Gore-tex modified Blalock Taussig shunt, and again at 3 years old for formation of a bidirectional Glenn anastomosis. Car...

متن کامل

A case of percutaneous modified Blalock-Taussig shunt downsize with multiple stent-in-graft technique

Corresponding author: Roland Fiszer MD, PhD, Department of Congenital Heart Diseases and Paediatric Cardiology, Medical University of Silesia, Silesian Center for Heart Diseases, 9 Curie-Skłodowskiej St, 41-800 Zabrze, Poland, phone: +48 504 125 057, e-mail: [email protected] Received: 7.10.2015, accepted: 8.12.2015. A case of percutaneous modified Blalock-Taussig shunt downsize with multipl...

متن کامل

Successful percutaneous transluminal balloon angioplasty and thrombolysis of a thrombosed bovine mesenteric venous graft after a modified Blalock-Taussig shunt Modifiye Blalock-Taussig şantı sonrası tromboz gelişen sığır mezenterik venöz greftin transkütan yolla başarılı balon anjiyoplastisi ve trombolizi

Duktus bağımlı siyanotik doğuştan kalp hastalığı olan beş aylık erkek bebeğe 4 mm’lik sığır mezenterik ven grefti ile palyasyon amaçlı modifiye Blalock-Taussig şant ameliyatı uygulandı. Ameliyat sonrası yedinci günde tekrar tıkanan şant cerrahi olarak revize edildi. Ancak, ikinci ameliyattan altı gün sonra greftte tekrar retromboz tespit edildi. Şant materyaline perkütan yolla başarılı bir şeki...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Revista espanola de cardiologia

دوره 62 10  شماره 

صفحات  -

تاریخ انتشار 2009