Physiological Measurements NEW APPROACH TO HAEMOGLOBINOMETRY BASED ON REFLECTANCE PHOTOMETRY
نویسندگان
چکیده
This paper describes a new approach to haemoglobinometry based on reflectance photometry using pretreated cell strip. A disposable cell strip is designed to absorb standardised volume of blood from a finger prick without any volumetric measuring apparatus. Pretreatment of the cell oxidises haemoglobin to methaemoglobin, thereby eliminating the errors of Tallqvist's method. The behavior of blood cells on chemically treated as well as untreated filter paper is studied by scanning electron microscopy. The principle behind the proposed method is used to fabricate a small, cheap and portable haemoglobinometer using LED's and suitable sensors. This technique provides a simple and reliable means of ascertaining haemoglobin content in blood for routine as well as field use. INTRODUCTION Haemoglobin percentage in blood is a diagnostic parameter for knowing different kind of anaemia. The conventional clinical methods [l,2] are cumbersome for field use. This is because these techniques involve diluting fluids, pipettes and use of standards. Further; fairly long time is required for a chemical reaction to be completed. The optical wedge method [33 and Tallqvist's filter paper technique L43 are of little clinical use as the colour matching gives erratic results. In this paper, experimental investigations leading to the development of haemoglobinometer based on reflectance photometry using chemically pretreated filter paper are presented. The scanning electron microscopy is used to study the behavior of blood cells. The choice of chemical used is confirmed by spectroscopic studies. In addition, colorimetric estimation using 640 nm filter is also presented. EXPERIMENTAL INVESTIGATIONS Blood samples Blood samples for this study were routinely obtained from the clinical chemistry laboratory. Specimens were collected by venipuncture into EDTA, containing evacuated blood collection tubes and kept at 4 degree cent. before and during transport to the lab. within 24 hrs. of collection. Further, capillary blood samples were obtained by finger prick with a spring loaded sterile lancet, Colorimetric estimation To 0.02 ml of blood was added 4 ml of N/10 HC1 and 0.1% NaN02 separately. Brownish red colour so obtained showed gradual increase in optical density with an increase in Hb content as shown in Table I.
منابع مشابه
Image Enhancement via Reducing Impairment Effects on Image Components
In this paper, a new approach is presented for improving image quality. It provides a new outlook on how to apply the enhancment methods on images. Image enhancement techniques may deal with the illumination, resolution, or distribution of pixels values. Issues such as the illumination of the scene and reflectance of objects affect on image captures. Generally, the pixels value of an image is ...
متن کاملExample-based Reflectance Estimation for Capturing Relightable Models of People
We present a new approach to reflectance estimation for dynamic scenes. Non-parametric image statistics are used to transfer reflectance properties from a static example set to a dynamic image sequence. The approach allows reflectance estimation for surface materials with inhomogeneous appearance, such as those which commonly occur with patterned or textured clothing. Material reflectance prope...
متن کاملA Nonlinear Voltage Stability Index based on Vector Analysis Method and Measurements of Active and Reactive Powers of Power System
This paper proposes a new voltage stability assessment method based on vector analysis method. This index extraction process relies on measurements of active and reactive powers from connected buses to the generator buses. Therefore, a limit for beginning of voltage collapse is determined based on the maximum power transfer theory. On the other hand, when the system requires load shedding, a ne...
متن کاملSurface reflectance of Mars observed by CRISM/MRO: 1. Multiangle Approach for Retrieval of Surface Reflectance from CRISM observations (MARSReCO)
[1] This article addresses the correction for aerosol effects in near-simultaneous multiangle observations acquired by the Compact Reconnaissance Imaging Spectrometer for Mars (CRISM) aboard the Mars Reconnaissance Orbiter. In the targeted mode, CRISM senses the surface of Mars using 11 viewing angles, which allow it to provide unique information on the scattering properties of surface material...
متن کاملA taxonomic study of blue-green algae based on morphological, physiological and molecular characterization in Yazd province terrestrial ecosystems (Iran)
Based on the limited resources available to algal flora in Yazd province in the center of Iran, cultivation, purification and identification of soil algae from seven sites was performed in summer 2013. The soil samples were processed for analysis of Cd, Pb contents. The present paper attempts to analyze survey of soil blue-green algal identification in different types of stations, using morphol...
متن کامل