Reduced ventricular volumes and improved systolic function with cardiac resynchronization therapy: a randomized trial comparing simultaneous biventricular pacing, sequential biventricular pacing, and left ventricular pacing.

نویسندگان

  • Rajni K Rao
  • Uday N Kumar
  • Jill Schafer
  • Esperanza Viloria
  • David De Lurgio
  • Elyse Foster
چکیده

BACKGROUND Cardiac resynchronization therapy has emerged as an important therapy for advanced systolic heart failure. Among available cardiac resynchronization therapy pacing modes that restore ventricular synchrony, it is uncertain whether simultaneous biventricular (BiV), sequential BiV, or left ventricular (LV) pacing is superior. The Device Evaluation of CONTAK RENEWAL 2 and EASYTRAK 2: Assessment of Safety and Effectiveness in Heart Failure (DECREASE-HF) trial is the first randomized trial comparing these 3 cardiac resynchronization therapy modalities. METHODS AND RESULTS The DECREASE-HF Trial is a multicenter trial in which 306 patients with New York Heart Association class III or IV heart failure, an LV ejection fraction < or = 35%, and a QRS duration > or = 150 ms were randomized to simultaneous BiV, sequential BiV, or LV pacing. LV volumes and systolic and diastolic function were assessed with echocardiography at baseline, 3 months, and 6 months. All groups had a significant reduction in LV end-systolic and end-diastolic dimensions (P<0.001). The simultaneous BiV pacing group had the greatest reduction in LV end-systolic dimension (P=0.007). Stroke volume (P<0.001) and LV ejection fraction (P<0.001) improved in all groups with no difference across groups. CONCLUSIONS Compared with LV pacing, simultaneous BiV pacing was associated with a trend toward greater improvement in LV size. There is little difference between simultaneous BiV pacing and sequential BiV pacing as programmed in this trial.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A comparison of cardiac resynchronization by sequential biventricular pacing and left ventricular pacing to simultaneous biventricular pacing: rationale and design of the DECREASE-HF clinical trial.

BACKGROUND The first generation of cardiac resynchronization therapy (CRT) devices approved for the treatment of heart failure used simultaneous biventricular (BiV) pacing to achieve ventricular resynchronization. Left ventricular pacing alone and sequential BiV pacing also show promise as alternative ways to deliver CRT, but have not been studied together in a large randomized trial. METHODS...

متن کامل

Left Ventricular Reverse Remodeling With Biventricular Versus Right Ventricular Pacing in Patients With Atrioventricular Block and Heart Failure in the BLOCK HF Trial.

BACKGROUND Biventricular pacing in heart failure (HF) improves survival, relieves symptoms, and attenuates left ventricular (LV) remodeling. However, little is known about biventricular pacing in HF patients with atrioventricular block because they are typically excluded from biventricular trials. METHODS AND RESULTS The Biventricular versus Right Ventricular Pacing in Heart Failure Patients ...

متن کامل

Sequential versus simultaneous biventricular resynchronization for severe heart failure: evaluation by tissue Doppler imaging.

BACKGROUND Cardiac resynchronization therapy (CRT) by means of simultaneous biventricular pacing improves left ventricular systolic performance and synchrony in patients with heart failure and bundle-branch block. We used tissue tracking and 3D echocardiography to evaluate the impact of sequential CRT with individualized interventricular delay programming. METHODS AND RESULTS Twenty consecuti...

متن کامل

Patient Selection for Cardiac Resynchronization Therapy

Cardiac resynchronization therapy (CRT) is a relatively new therapy for patients with symptomatic heart failure resulting from systolic dysfunction. CRT is achieved by simultaneously pacing both the left and right ventricles. Biventricular pacing resynchronizes the timing of global left ventricular depolarization and improves mechanical contractility and mitral regurgitation. Published clinical...

متن کامل

Improvement in pump function with endocardial biventricular pacing increases with activation time at the left ventricular pacing site in failing canine hearts.

Recently, attention has been focused on comparing left ventricular (LV) endocardial (ENDO) with epicardial (EPI) pacing for cardiac resynchronization therapy. However, the effects of ENDO and EPI lead placement at multiple sites have not been studied in failing hearts. We hypothesized that differences in the improvement of ventricular function due to ENDO vs. EPI pacing in dyssynchronous (DYSS)...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 115 16  شماره 

صفحات  -

تاریخ انتشار 2007