00 1 A Study of RHIC Crystal Collimation
نویسندگان
چکیده
The Relativistic Heavy Ion Collider (RHIC) will experience increasing longitudinal and transverse heavy ion emittances, mostly due to intra-beam scattering (IBS). The experiments in RHIC are expected to not only have reduced luminosi-ties due to IBS but also an unwanted beam halo. Primary betatron collimators will be used to remove the large amplitude particles. The efficiency of the primary collimator in RHIC depends very much on the alignment of the jaws which needs to be within few micro-radians for the best conditions. As proposed by V. Biryukov [1] bent crystals could be used to improve the efficiency of an existing collimation system by installing them upstream of the collimator jaws. Bent crystals have been successfully used in SPS, Protvino and Fermilab for extraction of the beam particles channeled through them. This study examines possible improvements of the primary collimator system for heavy ions at RHIC by use of bent crystals. Bent crystals will reduce the collimator jaws alignment requirement and will increase collimator efficiency thereby reducing detector background. 1
منابع مشابه
N ov 2 00 1 Progress in Crystal Extraction and Collimation
Recent IHEP Protvino experiments show efficiencies of crystal-assisted slow extraction and collimation of 85.3±2.8%, at the intensities of the chan-neled beam on the order of 10 12 proton per spill of ∼2 s duration. The obtained experimental data well follows the theory predictions. We compare the measurements against theory and outline the theoretical potential for further improvement in the e...
متن کاملCoherent effects in crystal collimation
We present theory for coherent effects observed in crystal collimation experiments that is in good quantitative agreement with RHIC and Tevatron data. We show that coherent scattering in a bent crystal strongly amplifies beam diffusion, with an effective radiation length shortened by orders of magnitude compared to amorphous material. This coherent scattering could replace the traditional amorp...
متن کاملThe Two Stage Crystal Collimator for RHIC
The use of a two stage crystal collimation system in the RHIC yellow ring is examined. The system includes a copper beam scraper and a bent silicon crystal. While scrapers were installed in both of the RHIC rings before the year 2000 run, the crystal is installed for the 2001 run in one ring only, forming a two stage collimation system there. We present simulations of the expected channeling th...
متن کاملHigh-efficiency beam extraction and collimation using channeling in very short bent crystals.
A silicon crystal was used to channel and extract 70 GeV protons from the U-70 accelerator with an efficiency of 85.3+/-2.8%, as measured for a beam of approximately 10(12) protons directed towards crystals of approximately 2 mm length in spills of approximately 2 s duration. The experimental data follow very well the prediction of Monte Carlo simulations. This demonstration is important in dev...
متن کاملHigh Energy High Intensity Hadron Beams Simulation of "Crystal", the bent crystal based collimation experiment in the SPS
Crystal collimation is a possible variant of the two-stage collimation systems used in modern accelerators, by which the collimation efficiency may be strongly enhanced. An experiment is proposed in the CERN-SPS to check the improved performance on crystal collimation. Here we present the experiment layout and we perform simulations showing in quantitative manner the expected behavior of crysta...
متن کامل