Development of a Whole Slide Imaging System on Smartphones and Evaluation With Frozen Section Samples
نویسندگان
چکیده
BACKGROUND The aim was to develop scalable Whole Slide Imaging (sWSI), a WSI system based on mainstream smartphones coupled with regular optical microscopes. This ultra-low-cost solution should offer diagnostic-ready imaging quality on par with standalone scanners, supporting both oil and dry objective lenses of different magnifications, and reasonably high throughput. These performance metrics should be evaluated by expert pathologists and match those of high-end scanners. OBJECTIVE The aim was to develop scalable Whole Slide Imaging (sWSI), a whole slide imaging system based on smartphones coupled with optical microscopes. This ultra-low-cost solution should offer diagnostic-ready imaging quality on par with standalone scanners, supporting both oil and dry object lens of different magnification. All performance metrics should be evaluated by expert pathologists and match those of high-end scanners. METHODS In the sWSI design, the digitization process is split asynchronously between light-weight clients on smartphones and powerful cloud servers. The client apps automatically capture FoVs at up to 12-megapixel resolution and process them in real-time to track the operation of users, then give instant feedback of guidance. The servers first restitch each pair of FoVs, then automatically correct the unknown nonlinear distortion introduced by the lens of the smartphone on the fly, based on pair-wise stitching, before finally combining all FoVs into one gigapixel VS for each scan. These VSs can be viewed using Internet browsers anywhere. In the evaluation experiment, 100 frozen section slides from patients randomly selected among in-patients of the participating hospital were scanned by both a high-end Leica scanner and sWSI. All VSs were examined by senior pathologists whose diagnoses were compared against those made using optical microscopy as ground truth to evaluate the image quality. RESULTS The sWSI system is developed for both Android and iPhone smartphones and is currently being offered to the public. The image quality is reliable and throughput is approximately 1 FoV per second, yielding a 15-by-15 mm slide under 20X object lens in approximately 30-35 minutes, with little training required for the operator. The expected cost for setup is approximately US $100 and scanning each slide costs between US $1 and $10, making sWSI highly cost-effective for infrequent or low-throughput usage. In the clinical evaluation of sample-wise diagnostic reliability, average accuracy scores achieved by sWSI-scan-based diagnoses were as follows: 0.78 for breast, 0.88 for uterine corpus, 0.68 for thyroid, and 0.50 for lung samples. The respective low-sensitivity rates were 0.05, 0.05, 0.13, and 0.25 while the respective low-specificity rates were 0.18, 0.08, 0.20, and 0.25. The participating pathologists agreed that the overall quality of sWSI was generally on par with that produced by high-end scanners, and did not affect diagnosis in most cases. Pathologists confirmed that sWSI is reliable enough for standard diagnoses of most tissue categories, while it can be used for quick screening of difficult cases. CONCLUSIONS As an ultra-low-cost alternative to whole slide scanners, diagnosis-ready VS quality and robustness for commercial usage is achieved in the sWSI solution. Operated on main-stream smartphones installed on normal optical microscopes, sWSI readily offers affordable and reliable WSI to resource-limited or infrequent clinical users.
منابع مشابه
Development of Whole Slide Imaging on Smartphones and Evaluation With ThinPrep Cytology Test Samples: Follow-Up Study.
BACKGROUND The smartphone-based whole slide imaging (WSI) system represents a low-cost and effective alternative to automatic scanners for telepathology. In a previous study, the development of one such solution, named scalable whole slide imaging (sWSI), was presented and analyzed. A clinical evaluation of its iOS version with 100 frozen section samples verified the diagnosis-readiness of the ...
متن کاملDigital Teleconsultation: Clinical Perspectives
Immediate analysis of specimens, such as rapid cytology adequacy determination and frozen section interpretation are now employed using real time screen sharing and whole slide imaging technologies. Both have been shown to be accurate and have proven to be substantial productivity enhancers for pathologists. Secondary consultation practices have employed predominantly the whole slide imaging ap...
متن کاملبررسی روایی نتایج روش برش انجمادی در مقایسه با روش برشهای دائمی (روش استاندارد) در تشخیص بیماری هیرشپرونگ
Background and Objectives: Hirschsprung's disease is one of the congenital movement disorders of the bowel whose accurate and timely diagnosis in childhood is important. The disease occurs due to lack of ganglion cells in the distal part of the digestive system and leads to functional obstruction of the colon. Recently, by the frozen section method, the diagnosis and treatment of the disease is...
متن کاملDiagnostic Accuracy of Frozen Section in Comparison With Fine Needle Aspiration Cytology in Thyroid Lesions – A Prospective Study
Background and Objectives: Thyroid gland because of its superficial location is amenable to direct physical examination. Clinical assessment of thyroid lesions by means of physical examination, thyroid scans and ultrasonography is not completely reliable. Fine needle aspiration cytology (FNAC) is the most cost-effective, safe and an initial diagnostic test in the pre-operative evaluation of thy...
متن کاملACCURACY OF INTRAOPERATIVE FROZEN SECTION DIAGNOSIS AND TOUCH IMPRINT CYTOLOGY: STUDY ON 1000 CONSECUTIVE CASES
Frozen section and touch imprint cytology are important diagnostic procedures for surgeons during operation and must be accurate if the patient is to receive maximum benefit. To assess the accuracy of intraoperative pathologic consultation including frozen section and touch imprint cytology during a five year period (1995- 2000), a retrospective survey of 1000 consecutive cases of frozen s...
متن کامل