Prospective motion correction with FID-triggered image navigators

نویسندگان

  • Maryna Babayeva
  • Pavel Falkovskiy
  • Tom Hilbert
  • Guillaume Bonnier
  • Bénédicte Maréchal
  • Reto Meuli
  • Jean-Philippe Thiran
  • Rolf Gruetter
  • Tobias Kober
چکیده

shaking; (b) Changes in volumetric measurements and image quality due to motion correction). The p-value is shown as calculated with the Wilcoxon rank-sum test when comparing the volumes with and without correction. 1417 Prospective motion correction with FID-triggered image navigators Maryna Babayeva, Pavel Falkovskiy, Tom Hilbert, Guillaume Bonnier, Bénédicte Maréchal, Reto Meuli, Jean-Philippe Thiran, Rolf Gruetter, Gunnar Krueger, and Tobias Kober Siemens ACIT CHUV Radiology, Siemens Healthcare IM BM PI, & Department of Radiology, University Hospital (CHUV), Lausanne, Switzerland, LTS5, École Polytechnique Fédérale de Lausanne, Lausanne, Switzerland, Department of Radiology, University Hospital (CHUV), Lausanne, Switzerland, CIBM, École Polytechnique Fédérale de Lausanne and University of Geneva, Switzerland

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prospective head motion correction using FID-guided on-demand image navigators.

PURPOSE We suggest a motion correction concept that employs free-induction-decay (FID) navigator signals to continuously monitor motion and to guide the acquisition of image navigators for prospective motion correction following motion detection. METHODS Motion causes out-of-range signal changes in FID time series that, and in this approach, initiate the acquisition of an image navigator. Co-...

متن کامل

Motion Correction in Magnetic Resonance Imaging Using the Signal of Free-Induction-Decay

Magnetic resonance imaging (MRI) is highly susceptible to subject’s motion and can significantly degrade image quality. In brain MRI exams, involuntary headmovements can affect the sampled k-space data. Such unintended alterations may result in visible image artifacts such as blurring, ghosting and others, and therefore potentially disqualify the image fromdiagnostic purposes. Methods to charac...

متن کامل

Hybrid Prospective & Retrospective Head Motion Correction System to Mitigate Cross-Calibration Errors

INTRODUCTION – Correction of head motion artifacts is essential for clinically acceptable image quality. This is especially important for long scans, such as DTI, fMRI, and high-resolution structural scans. Prospective motion-correction using stereovision systems [1,2] have been suggested to perform real-time head motion-correction without necessitating the acquisition of additional MR-based na...

متن کامل

Motion correction in simultaneous PET/MR brain imaging using sparsely sampled MR navigators: a clinically feasible tool

BACKGROUND We present a study performing motion correction (MC) of PET using MR navigators sampled between other protocolled MR sequences during simultaneous PET/MR brain scanning with the purpose of evaluating its clinical feasibility and the potential improvement of image quality. FINDINGS Twenty-nine human subjects had a 30-min [(11)C]-PiB PET scan with simultaneous MR including 3D navigat...

متن کامل

Real-time Motion Detection for Structural Brain Imaging Using Multi-Coil FID Navigators

Fig. 2 Uncorrected (black) and corrected (blue) navigator signal of an MP-RAGE measurement. Head position was changed during the period marked violet. The green bars show motion threshold at that moment, red points mark motion-corrupted TRs, which are rescanned at the end (pink bar). Cyan shows the online regression time course. Real-time Motion Detection for Structural Brain Imaging Using Mult...