Comparative study of minimal fresh gas flow used in Lack-Plus and Lack’s circuit in spontaneously breathing anesthetized adults

نویسندگان

  • Sunchai Theerapongpakdee
  • Thepakorn Sathitkarnmanee
  • Sirirat Tribuddharat
  • Siwalai Sucher
  • Maneerat Thananun
  • Duangthida Nonlhaopol
چکیده

BACKGROUND The Lack's circuit is a co-axial Mapleson A breathing system commonly used in spontaneously breathing anesthetized adults but still requires high fresh gas flow (FGF). The Lack-Plus circuit was invented with the advantage of lower FGF requirement. The authors compared the Lack-Plus and Lack's circuit for the minimal FGF requirement with no rebreathing in spontaneously breathing anesthetized adults. METHODS This was a randomized crossover study. We enrolled 24 adult patients undergoing supine elective surgery, with a body mass index ≤30 kg/m2 and an American Society of Anesthesiologists physical status I-II. They were randomly allocated to group 1 (LP-L) starting with Lack-Plus then switching to Lack's circuit or group 2 (L-LP) (with the reverse pattern). After induction and intubation, anesthesia was maintained with 50% N2O/O2 and desflurane (4%-6%) plus fentanyl titration to maintain an optimal respiratory rate between 10 and 16/min. Starting with the first circuit, all the patients were spontaneously breathing with a FGF of 4 L/min for 10 min, gradually decreased by 0.5 L/min every 5 min until FGF was 2.5 L/min. End-tidal CO2, inspired minimum CO2 (ImCO2), mean arterial pressure, and oxygen saturation were recorded until rebreathing (ImCO2 >0 mmHg) occurred. The alternate anesthesia breathing circuit was used and the measurements were repeated. RESULTS The respective minimal FGF at the point of rebreathing for the Lack-Plus and Lack's circuit was 2.7±0.8 and 3.3±0.5 L/min, respectively, p<0.001. At an FGF of 2.5 L/min, the respective ImCO2 was 1.5±2.0 and 4.2±2.6 mmHg, respectively, p<0.001. CONCLUSION The Lack-Plus circuit can be used safely and effectively, and it requires less FGF than Lack's circuit in spontaneously breathing anesthetized adults.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Imposed work of breathing during high-frequency oscillatory ventilation: a bench study

INTRODUCTION The ventilator and the endotracheal tube impose additional workload in mechanically ventilated patients breathing spontaneously. The total work of breathing (WOB) includes elastic and resistive work. In a bench test we assessed the imposed WOB using 3100 A/3100 B SensorMedics high-frequency oscillatory ventilators. METHODS A computer-controlled piston-driven test lung was used to...

متن کامل

Baby EAR circuit: a clinical determination of optimal fresh gas flow in spontaneous breathing anesthesia.

BACKGROUND Baby EAR circuit is a new modified enclosed afferent reservoir anesthetic breathing system invented to use in pediatric patients. By following His Majesty the King of Thailand's self-sufficiency philosophy, the circuit is simplymade of low-cost and easy-to-find materials in the operating room. OBJECTIVE Investigate clinical use of the circuit and to find the optimal fresh gas flow ...

متن کامل

Fresh gas requirements of an enclosed afferent reservoir breathing system in anaesthetized, spontaneously breathing adults.

Using two methods of determining the onset of rebreathing, we have determined the minimum fresh gas flow rate (VF) of the Ohmeda enclosed afferent reservoir breathing system (EAR) in anaesthetized, spontaneously breathing adults. Rebreathing as defined by the Kain and Nunn criteria did not occur when the VF/VE ratio was greater than 0.70. A mathematical model was used to calculate the degree of...

متن کامل

A clinical determination of optimal fresh gas flow in a baby EAR circuit.

OBJECTIVE Baby EAR circuit is a new modified enclosed afferent reservoir anesthetic breathing system for pediatric patients. By following His Majesty the King of Thailand's self-sufficiency philosophy, the circuit is simple and made of low-cost and easy-to-find materials found in the operating room. This present study was to investigate clinical use of the circuit and to find the optimal fresh ...

متن کامل

مقایسه لوله دهانی حلقی کافدار با لوله تراشه در حفظ راه هوائی و تهویه بیماران تحت بیهوشی عمومی با تنفس خودبخودی

Background: Cuffed pharyngeal tube is a device designed for ventilation of anesthetized patients. CPT has advantages over face mask including: maintaining of face mask can be difficult and boring after several minutes and mobility of the practitioner is reduced due to involvement of hands. Mask pressure can cause soft tissue and nerve damage around the nose. Anesthetic gas leakage from the mask...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2016