Rapid evaluation of left ventricular volume and mass without breath-holding using real-time interactive cardiac magnetic resonance imaging system.

نویسندگان

  • S Kaji
  • P C Yang
  • A B Kerr
  • W H Tang
  • C H Meyer
  • A Macovski
  • J M Pauly
  • D G Nishimura
  • B S Hu
چکیده

OBJECTIVES The purpose of this study was to validate cardiac measurements derived from real-time cardiac magnetic resonance imaging (MRI) as compared with well-validated conventional cine MRI. BACKGROUND Although cardiac MRI provides accurate assessment of left ventricular (LV) volume and mass, most techniques have been relatively slow and required electrocardiogram (ECG) gating over many heart beats. A newly developed real-time MRI system allows continuous real-time dynamic acquisition and display without cardiac gating or breath-holding. METHODS Fourteen healthy volunteers and nine patients with heart failure underwent real-time and cine MRI in the standard short-axis orientation with a 1.5T MRI scanner. Nonbreath-holding cine MRI was performed with ECG gating and respiratory compensation. Left ventricular end-diastolic volume (LVEDV), left ventricular endsystolic volume (LVESV), ejection fraction (EF) and LV mass calculated from the images obtained by real-time MRI were compared to those obtained by cine MRI. RESULTS The total study time including localization for real-time MRI was significantly shorter than cine MRI (8.6 +/- 2.3 vs. 24.7 +/- 3.5 min, p < 0.001). Both imaging techniques yielded good quality images allowing cardiac measurements. The measurements of LVEDV, LVESV, EF and LV mass obtained with real-time MRI showed close correlation with those obtained with cine MRI (LVEDV: r = 0.985, p < 0.001; LVESV: r = 0.994, p < 0.001; EF: r = 0.975, p < 0.001; LV mass: r = 0.977, p < 0.001). CONCLUSIONS Real-time MRI provides accurate measurements of LV volume and mass in a time-efficient manner with respect to image acquisition.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Correlation between Left and Right Ventricular Ejection Fractions in Patients with Ischemic Heart Disease, Documented by Cardiac Magnetic Resonance Imaging

Introduction: The correlation between right and left ventricular ejection fractions (RVEF and LVEF, respectively) has been studied in only a small number of patients with a marked decrease in RVEF and LVEF. The aim of the present study was to compare LVEF and RVEF in patients with ischemic heart disease. RVEF and LVEF were measured by Cardiovascular Magnetic Resonance (CMR) imaging. Materials a...

متن کامل

Single-breathhold, four-dimensional, quantitative assessment of LV and RV function using triggered, real-time, steady-state free precession MRI in heart failure patients.

PURPOSE To validate a novel, real-time, steady-state free precession (SSFP), single-breathhold technique for the assessment of left ventricular (LV) and right ventricular (RV) function in heart failure patients. MATERIALS AND METHODS A total of 20 heart failure patients (mean age 59 +/- 17 years) underwent scanning with our new, real-time, spiral SSFP sequence in which each cardiac phase was ...

متن کامل

STRUCTURE AND FUNCTION Rapid Evaluation of Right and Left Ventricular Function and Mass Using Real-Time True-FISP Cine MR Imaging Without Breath-Hold: Comparison with Segmented True-FISP Cine MR Imaging with Breath-Hold

Purpose. To evaluate the accuracy of cardiac function measured with real-time true fast imaging with steady-state precession (True-FISP) cine without breath-hold compared with those measured from segmented True-FISP cine with breath-hold. Methods. Eighteen consecutive patients and six healthy volunteers were enrolled in the study group. Both realtime multislice True-FISP cine imaging without br...

متن کامل

Free-breathing real-time cardiac cine MR for evaluation of left-ventricular function: Comparison to standard multi-breath-hold cardiac cine MR in 50 patients

Background Electrocardiogram (ECG)-gated breath-hold cardiac cine magnetic resonance imaging (MRI) is generally accepted as the gold standard for left-ventricular (LV) volume assessment. However, it may fail in patients with arrhythmia, impaired breath-hold capacity, and poor ECG gating. Recently, sparse real-time (RT) cine using a prototype sequence with sparse sampling and iterative reconstru...

متن کامل

Right ventricular Hemodynamic Alteration after Pulmonary Valve Replacement in Children with Congenital Heart Disease

Introduction:  In patients who underwent surgery to repair Tetralogy of Fallot, right ventricular dilation from pulmonary regurgitation may be result in right ventricular failure, arrhythmias and cardiac arrest. Hence, pulmonary valve replacement may be necessary to reduce right ventricular volume overload. The aim of present study was to assess the effects of pulmonary valve replacement on rig...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 38 2  شماره 

صفحات  -

تاریخ انتشار 2001