Enhanced sensitivity in the analysis of trace organochlorine compounds by negative-ion mass spectrometry with ammonia as reagent gas.
نویسندگان
چکیده
A comparison of the performances of ammonia and methane as reagent gases for the analysis of trace organochlorine compounds by gas chromatography coupled to negative-ion chemical ionization mass spectrometry is performed in the present study. Examples of standard mixtures and human blood samples analyzed with both reagents in scan and selected-ion monitoring mode are shown. Important advantages are observed as a consequence of the use of ammonia. These concern detection and quantitation limits and the lower dependence of sensitivity on the degree of chlorine substitution of the compounds.
منابع مشابه
Negative-ion mass spectrometry of amphetamine congeners.
Negative-ion chemical ionization mass spectrometry with a conventional combined gas chromatograph-mass spectrometer has been used for the analysis of amphetamine-like compounds. Ammonia was used as the reagent gas, which gives rise to few but specific sample-fragment ions, such as (M--1)- as the base peak, m/z 91, and a smaller peak corresponding to the end part of the side chain. Five referenc...
متن کاملQualitative gas chromatography-mass spectrometry analyses using amines as chemical ionization reagent gases.
Ammonia is a very useful chemical ionization (CI) reagent gas for the qualitative analyses of compounds by positive ion gas chromatography-mass spectrometry (GCMS). The gas is readily available, inexpensive, and leaves no carbon contamination in the MS source. Compounds of interest to our laboratory typically yield abundant protonated or ammoniated species, which are indicative of a compound's ...
متن کاملCompositional and molecular species analysis of phospholipids by high performance liquid chromatography coupled with chemical ionization mass spectrometry.
High performance liquid chromatography (HPLC) was combined with chemical ionization mass spectrometry (CIMS) by the use of a moving-belt interface. The technique was employed for the analysis of naturally occurring phospholipids. Positive and negative ion mass spectra of various phospholipids such as phosphatidylcholine, phosphatidylethanolamine, phosphatidylserine, phosphatidylinositol, phosph...
متن کاملON-LINE SOLID-PHASE EXTRACTION AND LIQUID CHROMATOGRAPHY/PARTICLE BEAM-MASS SPECTROMETRY FOR DEGRADATION STUDIES OF SOME POLAR PESTICIDES IN WATER
An on-line automated method for photodegradation studies of isoproturon, diuron, atrazine, fenitrothion, and metoxuron by means of liquid chromatography/mass spectrometry (LC/MS) with particle beam (PB) interface is described. Surface water samples were first spiked with 50 µg/l of each pesticide and then exposed to the radiation of the medium-pressure mercury lamp. Next, in regular intervals o...
متن کاملEffect of ammonium on liquid- and gas-phase protonation and deprotonation in electrospray ionization mass spectrometry.
The electrospray ionization (ESI) is a complex process and there has been a long debate regarding the gas-phase effect on ion generation in the process. In this paper we investigated the effect of liquid chromatographic mobile phase additives (formic acid, aqueous ammonia and their combination) on the ESI signal intensities for a wide variety of compounds. The addition of a trace amount of aque...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of chromatography. A
دوره 823 1-2 شماره
صفحات -
تاریخ انتشار 1998