On the problems related to natural wet bulb temperature indirect evaluation for the assessment of hot thermal environments by means of WBGT.

نویسندگان

  • Francesca Romana D'Ambrosio Alfano
  • Boris Igor Palella
  • Giuseppe Riccio
چکیده

This paper deals with the indirect evaluation of the natural wet bulb temperature, t (nw), one of the two quantities forming the basis of the well-known wet bulb globe temperature (WBGT) index, considered worldwide to be a suitable and user-friendly tool for the preliminary assessment of hot thermal environments. This quantity can be measured by a wet bulb thermometer (a temperature sensor covered with a wetted wick naturally ventilated) or, if this is not available, calculated from other microclimatic parameters (i.e. the air temperature, the globe temperature, the air velocity, and the humidity) using a quite trivial energy balance equation. Because of the strong non-linear structure of such an equation, the risk of a multiplicity of steady state solutions could result in the failure to obtain a reliable index evaluation. To dispel all doubts, this work carries out an in-depth analysis of the heat balance equation to be solved for the indirect evaluation of the natural wet bulb temperature. A preliminary investigation of each heat flow term involved in the heat balance on the sensor has been carried out; in a second phase a special continuation method has been implemented, highlighting the effect of microclimatic parameters on the multiplicity of solutions. Results show that under free convection the evaluation produces a single solution only under uniform conditions, whereas in the presence of even slight differences between the air temperature and the mean radiant temperature, there can be as many as three solutions. This phenomenon, if confirmed by a further experimental investigation, could become a difficult matter since a sensor, in principle, has to read a unique value of the quantity measured. In any case, from a numerical point of view, the presence of many values of tnw greatly reduces the possibility of an indirect WBGT calculation from the other involved physical quantities; as a consequence, the indirect evaluation of WBGT should be clearly avoided based on ISO 7243 Standard.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigation of the compatibility of wet bulb globe temperature (WBGT) and predicted heat strain (PHS) in assessing the environmental conditions and heat load imposed on individuals: a case study in bakery workers

Introduction: This study was designed with the main purpose of examining the compatibility of the two indicators of wet bulb globe temperature (WBGT) and predicted thermal strain (PHS) in assessing the environmental conditions and the heat load imposed on the subjects. Method: In this cross-sectional study, 163 bakers were included in the study. Thermal stress was determined using the WBGT and...

متن کامل

The Assessment of Heat stress in the employees of the confectionery workshops based on WBGT and DI Indexes (A case study of Ilam city)

Background and Objective: Inappropriate atmospheric conditions are harmful factors that cause particular problems in certain seasons (summer or winter). The occupation of confectionery in the regions like Ilam causes severe problems due to the heat generated by the nature of the work (synthetic heat-generating processes) and the heat resulting from the climatic conditions in the region. Exposur...

متن کامل

Heat stress assessment according to the wet-bulb globe temperature (WBGT) index among workers of a steel mill in 2014

Background: Heat stress in the steel industry is considered as a serious threat to the health and safety of workers. A wide spectrum of complications and diseases from mild disorders such as burning sensation to fatal conditions such as thermal shock may occur due to uncontrolled thermal stress. In this study, heat stress assessment was performed according to the wet-bulb globe temperature (WBG...

متن کامل

اعتبار سنجی شاخص Humidex در ارزیابی استرس گرمایی مشاغل روباز در نواحی بیابانی و نیمه بیابانی کشور ایران

Introduction: Regarding development of several thermal indices and limitations of each, in this research applicability and validity of temperature- humidity index (Humidex) were examined against the standard heat index, Wet Bulb Globe Temperature -WBGT, as well as tympanic temperature of subjects. Material and Method:  This cross-sectional study was done on 163 subjects at spring and summer ...

متن کامل

بررسی کاربرد پذیری شاخص حرارتی ناراحتی اصلاح شده(MDI) در مشاغل روباز: مطالعه موردی معادن روباز استان تهران

Background and aims: Regarding development of several thermal indices and limitations of these indexes, in this research we were examined the applicability and validity of Modified discomfort index (MDI) in Outdoor occupational environments.  Methods: This cross-sectional study was done on 175 subjects in summer (2016) in 12 mines construction materials of Tehran Province. Environmental...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Annals of occupational hygiene

دوره 56 9  شماره 

صفحات  -

تاریخ انتشار 2012