Biodegradable collagen matrix implant versus mitomycin-C in trabeculectomy: five-year follow-up.

نویسندگان

  • Salvatore Cillino
  • Alessandra Casuccio
  • Francesco Di Pace
  • Carlo Cagini
  • Lucia Lee Ferraro
  • Giovanni Cillino
چکیده

BACKGROUND Clinical studies comparing trabeculectomy augmented with Ologen implant (OLO) versus trabeculectomy plus mitomycin-C (MMC) show contradictory results. To obtain long-term data, we report an extended 5-year follow-up trial evaluating the safety and efficacy of OLO as adjuvant compared to low-dosage MMC in trabeculectomy. METHODS Forty glaucoma patients (40 eyes) assigned to trabeculectomy with MMC or Ologen. PRIMARY OUTCOME target IOP at ≤21, ≤17 and ≤15 mmHg; complete and qualified success endpoint rates. SECONDARY OUTCOMES visual acuity (VA), mean deviation (MD), bleb evaluation, according to Moorfields Bleb Grading System (MBGS); spectral domain OCT (SD-OCT) bleb examination; number of glaucoma medications; frequency of postoperative complications. RESULTS The mean preoperative IOP was 26.7(±5.2) in MMC and 27.3(±6.0) in OLO eyes. Mean 60-month percentage reduction in IOP was significant in both groups [40.9 (±14.2) and 42.1(±13.3) P = 0.01], with an endpoint value of 15.2 (±3.2) and 15.8 (±2.3) mmHg in MMC and OLO, respectively. Complete success rates at ≤ 21 mmHg target IOP were 65% and 70%, at ≤17 mm Hg 60% and 55%, and at the ≤15 mm Hg target IOP 35% and 45% in MMC and OLO, respectively. The Kaplan-Meier curves did not differ both for complete and qualified success at any target IOP, with no significant endpoint intergroup difference at ≤ 15 mm Hg (log-rank P = 0.595).The intergroup MBGS scores differed due to reduced central and peripheral vascularity in MMC group (P = 0.027; P = 0.041). SD-OCT analysis denied differences in bleb height between MMC vs OLO (140.5 ± 20.3 μ vs 129.2 ± 19.3 μ respectively; P =0.079). Mean antiglaucoma medications were significantly reduced (P < 0.0005) from 2.5 (±0.3) to 1.2 (±0.4) in MMC and from 2.6 (±0.2) to 1.4 (±0.3) in OLO group, with no intergroup differences (P = 0.08). Six (30%) cystic thin avascular blebs without oozing were recorded in the MMC group and 2 (10%) in the OLO group, without intergroup difference (P = 0.235). CONCLUSIONS Our extended follow-up results confirm that Ologen implant yields efficacy and long-term success rates quite similar to MMC, with at least equivalent safety.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biodegradable Collagen Implants in Trabeculectomy.

Subconjunctival and subscleral fibrosis are the major causes of failure of filtering surgery. Antiproliferative agents have been successfully used to improve the long-term success of this surgery. Recent advancement in the field of glaucoma surgery has been the use of bioengineered, biodegradable, porous collagen-glycosaminoglycan matrix implant in the subconjunctival and/or subscleral space to...

متن کامل

High definition tomography to evaluate filtering bleb with biodegradable collagen implant in patients with high myopia

METHODS: A retrospective descriptive study of 10 patients (10 eyes) diagnosed with chronic open-angle glaucoma and high myopia. Patients underwent trabeculectomy with Ologen® implant, without mitomycin, with follow-up at one, three, six and nine months. Follow-up assessment included refraction, intraocular pressure (IOP), presence of complications, and examination of the bleb and implant using ...

متن کامل

Biodegradable 3D-Porous Collagen Matrix (Ologen) Compared with Mitomycin C for Treatment of Primary Open-Angle Glaucoma: Results at 5 Years

Purpose. To evaluate the effectiveness and safety of the Ologen as an aid for trabeculectomy performed for primary open-angle glaucoma compared with mitomycin C. Methods. In this prospective, randomized, parallel assignment, comparative study, 31 eyes of 21 primary open-angle glaucoma patients were allocated for trabeculectomy with the Ologen implant; another 32 eyes of 23 patients were treated...

متن کامل

Secondary subconjunctival implantation of a biodegradable collagen-glycosaminoglycan matrix to treat ocular hypotony following trabeculectomy with mitomycin C.

AIM Biodegradable collagen glycosaminoglycan matrices (CGM) have been introduced to glaucoma filtration surgery in order to prevent scarring of the filtering bleb. In this retrospective case series, we describe a new surgical concept for treating symptomatic ocular hypotony following filtration surgery with mitomycin C by a secondary subconjunctival implantation of a CGM. METHODS Depending on...

متن کامل

Trabeculectomy with combined use of subconjunctival collagen implant and low-dose mitomycin C.

PURPOSE To evaluate outcomes of trabeculectomy with use of a subconjunctival biodegradable collagen implant (Ologen) combined with mitomycin C (MMC). METHODS This retrospective study included 33 eyes of 24 patients with primary open-angle glaucoma who underwent fornix-based trabeculectomy with subconjunctival Ologen implant and MMC (0.1 mg/mL×1 min) between October 2008 and April 2010. Data p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • BMC ophthalmology

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2016