Case report of Pierre Robin sequence with severe upper airway obstruction who was rescued by fiberoptic nasotracheal intubation

نویسندگان

  • Satoru Takeshita
  • Hiroko Ueda
  • Tatenobu Goto
  • Daisuke Muto
  • Hiroki Kakita
  • Kazuo Oshima
  • Takahisa Tainaka
  • Takayuki Ono
  • Yoshiaki Kazaoka
  • Yasumasa Yamada
چکیده

BACKGROUND Pierre Robin sequence (PRS) refers to the association of micrognathia, glossoptosis, and airway obstruction. Cases with severe dyspnea due to upper airway obstruction immediately after birth are very rare. We here report two cases with PRS who developed severe dyspnea due to morphological abnormality immediately after birth and were rescued by fiberoptic nasotracheal intubation. CASE PRESENTATION The patient in case 1 had micrognathia and cleft palate, and his tongue protruded into the nasal cavity via a cleft palate. His invaginated tongue was considered an extreme type of glossoptosis and he was diagnosed as Pierre Robin sequence. The patient in case 2 also had micrognathia and cleft palate same as case 1 and accompanied some anomalad. Her chromosome analysis confirmed a diagnosis of 1p36 deletion syndrome and she diagnosed as 1p36 deletion syndrome complicated with Pierre Robin sequence. In both cases, tongue protruded into the nasal cavity via a cleft palate occupied pharynx and nasal cavity, resulting in severe dyspnea. Only the backside of the tongue was visible by laryngoscopy and oropharyngeal intubation was impossible. Therefore, fiberoptic nasotracheal intubation was done to secure the airway for resuscitation. CONCLUSION We conclude that extreme type of glossoptosis in PRS concludes tongue invaginated into nasal cavity which have not reported before and that such cases require resuscitation by fiberoptic intubation immediately after birth. As such, neonatologists should obtain the skill of fiberoptic intubation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Airway management for intubation in newborns with Pierre Robin sequence.

OBJECTIVES/HYPOTHESIS To review airway management in Pierre Robin sequence (PRS) newborns undergoing general anesthesia and to determine if endotracheal intubation is safe in this population. STUDY DESIGN Case series and retrospective chart review at a tertiary children's hospital. METHODS PRS newborns who underwent endotracheal intubation or other airway intervention before 3 months of age...

متن کامل

Tongue-lip adhesion in the management of Pierre Robin sequence with airway obstruction: technique and outcome.

BACKGROUND Airway obstruction and feeding difficulty can occur in patients born with Pierre Robin sequence. In select patients with pronounced micrognathia, surgical intervention to relieve the airway obstruction is necessary. The surgical indications and appropriate surgical procedure continue to have a great deal of controversy. The purpose of this study was to evaluate our experience of tong...

متن کامل

Using a nasopharyngeal airway during fiberoptic intubation in small children with a difficult airway.

BACKGROUND Induction of anesthesia and tracheal intubation in small children with a difficult airway is a challenging task. We report the experience with a procedure based on sevoflurane inhalation via a nasopharyngeal airway inserted early during induction before airway obstruction occurs. A pediatric fiberscope is used to perform a nasotracheal intubation via the opposite nostril. METHODS A...

متن کامل

Airtraq(®) laryngoscope-assisted fiberoptic bronchoscope intubation in a child with Pierre-Robin sequence: a case report.

We present a new strategy method of combining use of Airtraq(®) and fiberoptic bronchoscope (FOB) for tracheal intubation in 3-year-old child with Pierre-Robin sequence.

متن کامل

Usefulness of a Cook® airway exchange catheter in laryngeal mask airway-guided fiberoptic intubation in a neonate with Pierre Robin syndrome -A case report-

The case of a 33-day-old boy with Pierre Robin syndrome using a Cook® airway exchange catheter in laryngeal mask airway-guided fiberoptic intubation is presented. After induction with sevoflurane, classical reusable laryngeal mask airway (LMA) #1 was inserted and ultrathin fiberoptic bronchoscope (FOB) was passed through. A Cook® airway exchange catheter (1.6 mm ID, 2.7 mm OD) was passed throug...