Clinical Outcomes and Capsular Bag Stability of a Four-Point Haptic Bitoric Intraocular Lens.

نویسندگان

  • Florian T A Kretz
  • Detlev Breyer
  • Karsten Klabe
  • Gerd U Auffarth
  • Hakan Kaymak
چکیده

PURPOSE To evaluate the visual, refractive, and aberrometric outcomes of a bitoric intraocular lens (IOL) and its stability and alignment within the capsular bag. METHODS A retrospective study including 41 eyes of 24 patients with preexisting corneal astigmatism of 0.75 diopters or greater undergoing cataract surgery with implantation of the bitoric IOL AT TORBI 709M (Carl Zeiss Meditec, Jena, Germany). Visual and refractive outcomes were evaluated during a 3-month follow-up period. The misalignment between intended and real axis and the levels of corneal, internal, and ocular aberrations (KR-1W; Topcon, Tokyo, Japan) were also evaluated. RESULTS A total of 76% and 97% of eyes had a postoperative spherical equivalent within ± 0.50 and ± 1.00 diopters of emmetropia, respectively. Likewise, a total of 86% and 95% of eyes had a postoperative absolute value of refractive cylinder of 0.50 or less and 1.00 or less diopters, respectively. Mean postoperative corrected distance visual acuity was 0.00 logMAR (20/20 Snellen). Mean values of postoperative monocular and binocular uncorrected distance visual acuity were 0.10 and 0.00 logMAR (20/25 and 20/20 Snellen), respectively. The aberrometric analysis confirmed that the magnitude of ocular higher-order aberrations was mainly due to corneal optics and that the corneal astigmatism correction was sufficient with the toric IOL. Mean absolute IOL misalignment was 3.5° with values ranging from 0° to 10°. CONCLUSIONS The bitoric IOL AT TORBI 709M is able to provide a predictable correction of corneal astigmatism with low postoperative levels of ocular higher-order aberrations.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of number and position of intraocular lens haptics on anterior capsule contraction: a randomized, prospective trial

BACKGROUND The present study aimed to evaluate the degree of anterior capsule contraction (capsulorhexis contraction) with three different single-piece, hydrophilic acrylic intraocular lenses (IOLs). METHODS Patients were prospectively randomized to be implanted with one of three types of IOLs during cataract surgery: the Ophtec Precizon (IOL A), the Lucid Korea Microflex (IOL B), and the Car...

متن کامل

Glued capsular hook: technique for fibrin glue-assisted sutureless transscleral fixation of the capsular bag in subluxated cataracts and intraocular lenses.

We describe a technique that uses a capsular hook to obtain sutureless fibrin glue-assisted transscleral fixation of the capsular bag. The hook passes through a sclerotomy created under a scleral flap and engages the capsulorhexis rim, providing scleral fixation intraoperatively and postoperatively. A standard capsular tension ring expands the capsular fornix. The haptic of the hook is tucked i...

متن کامل

Outcomes of modified capsular tension ring versus sulcus-fixated foldable intraocular lens in subluxated lens secondary to Marfan syndrome

Purpose: To determine the outcomes of implantation of a modified Capsular Tension Ring (CTR) and a Posterior Chamber Intraocular Lens (PCIOL) in patients with subluxated lens secondary to Marfan Syndrome (MFS). Materials and methods: A total of 21 eyes of 12 patients with subluxated lens secondary to MFS undergoing Posterior Chamber Intraocular Lens (PCIOL) from March 2004 to February 2005 were...

متن کامل

Capsular Tension Rings

Cataract surgery in an eye with absent or weak zonules presents unique challenges for the anterior segment surgeon. With the introduction of the capsular tension ring (CTR), and its several modified versions, the ability to perform safe cataract extraction with the implantation of a stable and well-centered intraocular lens (IOL) within the capsular bag has increased substantially. In order to ...

متن کامل

Temporary Haptic Externalization and Four-point Fixation of Intraocular Lens in Scleral Fixation to Enhance Stability

PURPOSE To report the results of a new technique for intraocular lens scleral fixation of temporary haptic externalization and four-point fixation for enhanced stability. METHODS Two 10-0 polypropylene strands were fixed at two points 2 mm apart on each haptic of a conventional three-piece intraocular lens, using our previously reported method of temporary haptic externalization after injecto...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of refractive surgery

دوره 31 7  شماره 

صفحات  -

تاریخ انتشار 2015