Threshold contrast visibility of micro calcifications in digital mammography
نویسندگان
چکیده
The purpose of this study is to describe a method that allows the calculation of a contrast-detail curve for a particular system configuration using simulated micro calcifications into clinical mammograms. We made use of simulated templates of micro calcifications and adjusted their x-ray transmission coefficients and resolution to the properties of the mammographic system under consideration (4). We expressed the thickness of the simulated micro calcifications in terms of Al equivalence. In a first step we validated that the thickness of very small Al particles with well known size and thickness can be calculated from their x-ray transmission characteristics at a particular X-ray beam energy. Then, micro calcifications with equivalent diameters in the plane of the detector ranging from 300 to 800 μm and thicknesses, expressed in Al equivalent, covering 77 to 800 μm were simulated into the raw data of real clinical images. The procedure was tested on 2 system configurations: the GE Senographe 2000 D and the Se based Agfa Embrace DM1000 system. We adapted the X-ray transmissions and spatial characteristics of the simulated micro calcifications such that the same physical micro calcification could be simulated into images with the specific exposure parameters (Senographe 2000D: 28 kVp-Rh/Rh, Embrace DM1000: 28 kVp-Mo/Rh), compressed breast thickness (42+/-5mm) and detector under consideration. After processing and printing, 3 observers scored the visibility of the micro calcifications. We derived contrast-detail curves. This psychophysical method allows to summarize the performance of a digital mammography detector including processing and visualization.
منابع مشابه
Soft Copy Digital Mammography
Soft Copy Digital Mammography creen-film mammography (SFM) has been the standard method used for breast cancer screening and making a clinical diagnosis. It is a valuable modality for the detection and differentiation of breast calcifications. The advantages are the high spatital resolution, the convinient display, and inexpensiveness. However, it has some inherent limitations such as its low d...
متن کاملبررسی امکان تشخیص اتوماتیک میکروکلسیم های بافت پستان با استفاده از تکنیک دو انرژی تصویربرداری اشعه ایکس جهت تشخیص زودرس سرطان پستان
Background and purpose: Dual-energy mammography technique is used for improving the accuracy of breast cancer diagnosis especially in dense breast cases and also detection of micro-calcifications which are early signs of breast cancer. The purpose of this study was to investigate the automatic separation feasibility of micro-calcification images in breast tissue images and evaluating its accura...
متن کاملComparison of detection of micro calcifications for two clinical processing algorithms in digital mammography
Comparison of detection of micro calcifications for Comparison of detection of micro calcifications for Comparison of detection of micro calcifications for Comparison of detection of micro calcifications for two clinical processing algorithms in digital two clinical processing algorithms in digital two clinical processing algorithms in digital two clinical processing algorithms in digital mammo...
متن کاملThe threshold contrast thickness evaluated with different CDMAM phantoms and software
The European Commission recommends the CDMAM phantom as a tool to evaluate threshold contrast visibility in digital mammography [1, 2]. The use of the CDMAM phantom for that purpose has been proposed by Young [3] and other researchers. Recently, the phantom has been criticized because of poor reproducibility of the manufacturing process [4, 5], but it is still recommended by the European Commis...
متن کاملImproved Diagnostics by Assessing the Micromorphology of Breast Calcifications via X-Ray Dark-Field Radiography
Breast microcalcifications play an essential role in the detection and evaluation of early breast cancer in clinical diagnostics. However, in digital mammography, microcalcifications are merely graded with respect to their global appearance within the mammogram, while their interior microstructure remains spatially unresolved and therefore not considered in cancer risk stratification. In this a...
متن کامل