Counting nematodes with a microplate reader.

نویسندگان

  • A F Robinson
  • J A Veech
  • C M Heald
چکیده

The feasibility of counting plant-parasitic nematodes in aqueous suspensions by measuring light transmittance through aqueous suspensions with an ELISA microplate reader was explored. Absorbance readings for eggs or vermiform stages of three species were linearly related (R(2) > 0.99) to concentrations between 0 and 10,000 nematodes/ml. Coefficients of variation ranged from 12-23%, depending on the species and developmental stage used. The method, therefore, was at least as accurate as direct counts of nematodes in aliquots on a microscope and more than 100 times as fast. The method should have direct application in research programs on plant resistance to nematodes, nematode population dynamics, and nematode behavior.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Applications of a microplate reader in yeast physiology research.

Microplate readers have been useful assistants of researchers for several decades. This work is focused on the applications of a simple absorbance microplate reader in yeast physiology research, and its advantages and limitations in comparison with alternative methods are discussed. The two main procedures involved are measuring growth curves and monitoring the pH changes of medium using two di...

متن کامل

Counting Non-Aqueous Samples in the TopCount® Microplate Scintillation and Luminescence

The microplate format has become a standard for many biological assays such as high throughput screening for drug discovery and radioimmunoassays. Productivity with these high volume procedures has been limited by the amount of sample handling required and low sample counting throughput. Now, however, microplate assays can be efficiently counted in microplates with the Packard TopCount Micropla...

متن کامل

Application of Elisa Microplate Reader in Complement Fixation Test Used for Dourine Diagnosis. a Preliminary Study

The aim of the present work was to estimate the possibility of improving the objectiveness of complement fixation test (CFT) in the diagnosis of dourine by using an ELISA microplate reader. The investigations were carried out on control positive and negative sera and 16 sera obtained for a reference examination. Six modifications of CFT performing and reading methods were compared (tube, microp...

متن کامل

Rapid Measurement of Chlorophylls with a Microplate Reader

This paper describes a robust and rapid procedure for measuring chlorophyll using a microplate reader. The procedure enables direct translation of any published equation developed on a 1-cm pathlength spectrophotometer to any format microplate with any sample volume. Chlorophylls were extracted with methanol because it is compatible with cheap polystyrene plates; however, the principles apply t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nematology

دوره 24 1  شماره 

صفحات  -

تاریخ انتشار 1992