A Rapid and Convenient Procedure to Evaluate Optical Performance of Intraocular Lenses
نویسندگان
چکیده
A new portable lens scanner was developed and tested for measuring focal lengths and relative contrast transfer of monoand multifocal intraocular lenses (IOLs). A photograph of a natural scene was imaged in white light through an IOL in a water-filled cuvette, with their +21D base power largely neutralized by a −20D trial lens, using a USB monochrome video camera that could be focused via a laptop-controlled stepping motor from −8.5 to + 8.0D. The output of 10000 ON-OFF antagonistic “receptive fields” measuring the video image with adjustable diameter was continuously recorded by custom written software to quantify focus and relative contrast. Six monofocal and four multifocal IOLs, as well as two radial refractive gradient (RRG) lenses were measured. After calibration with trial lenses the optical powers and relative contrast transfer of monoand multifocal IOLs were readily measured. Refractive power profiles measured in RRG lenses closely matched data obtained from the manufacturer. The lens scanner uses a rapidly operating procedure, is portable and can be used to verify positions of the focal planes of monoand multifocal IOLs in less than 3 s.
منابع مشابه
کاربرد لنزهای داخل چشمی در جراحی کاتاراکت و عوامل تأثیرگذار بر دید بیمار
Introduction: With the growing and rapid development of refractive surgery, researches focus increasingly on improvement of visual quality after cataract surgery. Intraocular lenses (IOLs) were a successful effort in the field of cataract surgery. Despite significant advances in cataract surgery, several complications related to surgical technique and IOL design after surgery can cause vision c...
متن کاملRetinal images in optomechanical eye model with monofocal intraocular lens
Intraocular lens (IOL) is an artificial lens implanted into the eye. It usually replaces the existing crystalline lens, which is clouded over due to a cataract. In order to evaluate the optical performance of different IOLs an optomechanical model of human eye was developed. This model closely reproduces anatomical and optical properties of the average human eye. This makes it possible to measu...
متن کاملPhacotrabeculectomy and Implantation of Intraocular Lenses with Releasable Sutures and Antimetabolite Agents: Efficacy and Safety
Abstract Background: The aim of this study was to evaluate the efficacy and safety of phacoemulsification and the implantation of intraocular lenses (IOL) combined with trabeculectomy supplemented by releasable sutures and antimetabolite agents. Methods:Phacotrabeculectomy was performed in 36 eyes of 30 patients who hadmedically uncontrolle...
متن کاملImaging quality of multifocal intraocular lenses: automated assessment setup.
PURPOSE A new technique for the assessment of the optical quality of multifocal intraocular lenses (MIOLs) under monochromatic and polychromatic illumination is presented. METHODS The system provides, in a totally automated procedure, the modulation transfer function (MTF) of the lens under test for different axial positions of the object. The artificial eye admits different artificial cornea...
متن کاملInvestigation of Intraocular Lenses Surface Roughness by Atomic Force Microscopy
The aim of this study was to evaluate the surface roughness of intraocular lenses (IOLs) generated by the manufacturing process and to determine the roughness parameters of 3D surface using atomic force microscopy (AFM). Intraocular lenses commercially available from a single manufacturer: Pharmacia & Upjohn Co. were investigated. Three intraocular lenses, model 911A CeeOn Edge, were analyzed o...
متن کامل