Non Invasive Technique Based Evaluation of Electromyogram Signals Using Statistical Algorithm

نویسندگان

  • Tanu Sharma
  • Karan Veer
  • Ravinder Agarwal
چکیده

It is well known that Surface Electromyography is the activity that is being generated when voluntary contraction took place, so in this investigation, the study of Surface Electromyogram (SEMG) signals at different above-elbow muscles were carried out. These signals were easily acquired from surface of skin of the body using non-invasively house design of hardware system and various techniques for the interpretation of these recorded signals using one way repeated factorial analysis of variance were presented. Acquired data from selected locations of above elbow was interpreted for various features using LABVIEW soft scope and finally the computations of parameters were done. Result shows characteristics change in extracted feature values for different movements with respect to each position and movement.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A COMPARATIVE ANALYSIS OF WAVELET-BASED FEMG SIGNAL DENOISING WITH THRESHOLD FUNCTIONS AND FACIAL EXPRESSION CLASSIFICATION USING SVM AND LSSVM

This work presents a technique for the analysis of Facial Electromyogram signal activities to classify five different facial expressions for Computer-Muscle Interfacing applications. Facial Electromyogram (FEMG) is a technique for recording the asynchronous activation of neuronal inside the face muscles with non-invasive electrodes. FEMG pattern recognition is a difficult task for the researche...

متن کامل

Removing ECG Artifact from the Surface EMG Signal Using Adaptive Subtraction Technique

Background: The electrocardiogram artifact is a major contamination in the electromyogram signals when electromyogram signal is recorded from upper trunk muscles and because of that the contaminated electromyogram is not useful.Objective: Removing electrocardiogram contamination from electromyogram signals.Methods: In this paper, the clean electromyogram signal, electrocardiogram artifact and e...

متن کامل

ویبروآرتروگرافی، روشی نوین در تشخیص استئوآرتریت زانو

Vibroarthrography, A Novel Technique in Diagnosis of Knee Osteoarthritis A. Rahimi PhD PT , M.M. Roostayee MSc PT , D. Shahimoridi MSc PT Received: 02/02/06 Sent for Revision: 24/06/06 Received Revised Manuscript: 27/11/06 Accepted: 26/12/06 Background and Objective: Use of joint sound signals for diagnosis of knee joint disorders has been greatly welcomed since it is a non-invasive and inexpen...

متن کامل

Application of statistical techniques and artificial neural network to estimate force from sEMG signals

This paper presents an application of design of experiments techniques to determine the optimized parameters of artificial neural network (ANN), which are used to estimate force from Electromyogram (sEMG) signals. The accuracy of ANN model is highly dependent on the network parameters settings. There are plenty of algorithms that are used to obtain the optimal ANN setting. However, to the best ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014