Polyethylene Wear in Anatomic and Reversed Shoulder Prostheses
ثبت نشده
چکیده
INTRODUCTION: Polyethylene wear is a recurrent problem in joint arthroplasty. In addition to permanent deformation or complete destruction of the component, small debris particles are also associated to inflammation reaction of the surrounding bone, eventually leading to the failure of the bound between the implant and the host bone, and implant loosening. In anatomic total shoulder arthroplasty, failure of the glenoid polyethylene component is the main cause of complication, often related to periprosthetic osteolysis and aseptic loosening [1]. Polyethylene wear of anatomic prostheses has been clinically observed on retrieved glenoid components. For reversed shoulder prostheses, polyethylene wear is usually related to the scapular notching. However, the surface wear of the humeral cup is still unknown. In reversed prosthesis, the glenohumeral force is lower and the contact area is higher than in anatomic prosthesis [2]. Consequently, the contact pressure should thus be much lower, but the volumetric wear might be as important in reversed prostheses as in anatomic prostheses. The goal of this study was thus to estimate the volume of polyethylene wear of a reversed prosthesis, and compare it to an anatomic prosthesis, during one year of activities of daily living (ADL).
منابع مشابه
Comparison of polyethylene wear in anatomical and reversed shoulder prostheses.
Wear of polyethylene is associated with aseptic loosening of orthopaedic implants and has been observed in hip and knee prostheses and anatomical implants for the shoulder. The reversed shoulder prostheses have not been assessed as yet. We investigated the volumetric polyethylene wear of the reversed and anatomical Aequalis shoulder prostheses using a mathematical musculoskeletal model. Movemen...
متن کاملLong-term results and patient satisfaction after shoulder resurfacing.
BACKGROUND Shoulder resurfacing has regained popularity in recent years. This report presents the long-term (>20 years) results of this procedure with regard to patient satisfaction and implant survival. MATERIALS AND METHODS We followed up 61 patients who underwent shoulder resurfacing procedures (74 shoulders) for a minimum of 20 years or until death (7 additional patients were lost to foll...
متن کاملImproved survival for anatomic total shoulder prostheses
BACKGROUND AND PURPOSE Previously, implant survival of total shoulder prostheses was reported to be inferior to that of hemiprostheses. However, the use of total prostheses has increased in Norway due to reported good functional results. On this background, we wanted to study implant survival of 4 major shoulder prosthesis types in Norway between 1994 and 2012. PATIENTS AND METHODS The study ...
متن کاملSimulated joint and muscle forces in reversed and anatomic shoulder prostheses.
Reversed shoulder prostheses are increasingly being used for the treatment of glenohumeral arthropathy associated with a deficient rotator cuff. These non-anatomical implants attempt to balance the joint forces by means of a semi-constrained articular surface and a medialised centre of rotation. A finite element model was used to compare a reversed prosthesis with an anatomical implant. Active ...
متن کاملDegree of the Polyethylene Component Wear – a Predictive Factor for the Outcome of Total Hip Arthroplasty
In patients suffering of osteoarthritis of the hip (a degenerative condition of the hip that finally leads to anatomical and functional impairment of the joint), the only efficient treatment in advanced stages of the disease is the surgical replacement of the joint with a total hip prosthesis. Unfortunately, despite improving the composition of the materials from which these prostheses are made...
متن کامل