Supplementary Addendum to “Radiation dose of digital radiography (DR) versus micro-dose x-ray (EOS) on patients with adolescent idiopathic scoliosis: 2016 SOSORT- IRSSD “John Sevastic Award” Winner in Imaging Research”
نویسندگان
چکیده
Regarding the publication entitle "Radiation dose of digital radiography (DR) versus micro-dose x-ray (EOS) on patients with adolescent idiopathic scoliosis: 2016 SOSORT- IRSSD "John Sevastic Award" Winner in Imaging Research" in Scoliosis and Spinal Disorders, we would like to provide more details to readers about the dose calculated by simulation using PCXMC 2.0. In this study, the data and results are correct based on the given parameters and calculation provided in the manuscript. In the simulation of EOS micro-dose, only a 0.1 mm copper filter was applied. We agree with the suggestion from Dr. Pedersen and colleagues that the inclusion of a 1.5 mm aluminum filter together with the 0.1 mm copper reflects more realistic representation of X-ray filtration which would improve the accuracy of the simulation. We believe that this supplementary addendum would be beneficial to other researchers who are planning to conduct a similar study.
منابع مشابه
Radiation dose of digital radiography (DR) versus micro-dose x-ray (EOS) on patients with adolescent idiopathic scoliosis: 2016 SOSORT- IRSSD “John Sevastic Award” Winner in Imaging Research
BACKGROUND Patients with adolescent idiopathic scoliosis (AIS) frequently receive x-ray imaging at diagnosis and subsequent follow monitoring. The ionizing radiation exposure has accumulated through their development stage and the effect of radiation to this young vulnerable group of patients is uncertain. To achieve the ALARA (as low as reasonably achievable) concept of radiation dose in medic...
متن کاملA Comparison of Patients Absorption Doses with Bone Deformity Due to the EOS Imaging and Digital Radiology
Background: This study has aimed to measure the patient dose in entire spine radiography by EOS system in comparison with the digital radiography. Methods: EOS stereo-radiography was used for frontal and lateral view spine imaging in 41 patients in a prospective analytical study. A calibrated dose area product (DAP) meter was used for calibration of the DAP in EOS system. The accuracy and pr...
متن کاملEOS imaging versus current radiography: A health technology as-sessment study
Background: EOS is a 2D/3D muscle skeletal diagnostic imaging system. The device has been developed to produce a high quality 2D, full body radiographs in standing, sitting and squatting positions. Three dimensional images can be reconstructed via sterEOS software. This Health Technology Assessment study aimed to investigate efficacy, effectiveness and cost-effectiveness of new emerged EOS imag...
متن کاملThe Practice of Chest Radiography Using Different Digital Imaging Systems: Dose and Image Quality
Introduction: The study was undertaken to evaluate the practice of chest radiography using different digital imaging systems and its influence on dose and image quality. Materials and Methods: The study was carried out in two hospitals from March 2016 to June 2016. Sixty ambulatory patients aged 21 to 60 years who were able to cooperate without difficulty and weighed between 60 to 80 kg were ...
متن کاملImaging in the Diagnosis and Monitoring of Children with Idiopathic Scoliosis
The paper reviews the current imaging methods in the diagnosis and monitoring of patients with adolescent idiopathic scoliosis. Radiography is generally used in the initial diagnosis of the condition. Postero-anterior erect full spine radiograph is generally prescribed, and is supplemented by lateral full spine radiograph when indicated. To reduce the radiation hazard, only the area of interest...
متن کامل