Analysis of Accommodative Performance of a New Accommodative Intraocular Lens.

نویسندگان

  • Jorge L Alió
  • Aleksey N Simonov
  • Daniel Romero
  • Alexander Angelov
  • Yavor Angelov
  • Willem van Lawick
  • Michiel C Rombach
چکیده

PURPOSE To compare objective and subjective accommodation and visual acuities with a new accommodative intraocular lens (IOL) (Lumina; AkkoLens Clinical BV, Rijswijk, The Netherlands) with a monofocal IOL and young phakic eyes. METHODS In this prospective, randomized controlled clinical investigation, patients aged 51 to 85 years with symptomatic cataract were enrolled in the study. A total of 25 eyes were implanted with the accommodative IOL and 18 eyes received the monofocal Acrysof SA60AT IOL (Alcon Laboratories, Inc., Fort Worth, TX). Each group included 4 bilateral patients. An additional 20 phakic eyes of young patients aged 19 to 29 years were used to assess the restoration of accommodation. Subjective and objective accommodative amplitudes were evaluated by defocus curves and the WAM-5500 open-field Auto Ref/Keratometer (Grand Seiko, Tokyo, Japan), respectively. RESULTS The 1-year postoperative examination showed significantly better visual acuities with the accommodative IOL compared to the monofocal IOL, over a defocus range of -0.50 to -5.00 diopters (D) (P < 10-5), and revealed more than 50% of the visual acuities of the young phakic eyes at up to -3.50 D defocus. The depth of focus of the accommodative group exceeded that of the monofocal group by 2.52 ± 0.03 D in a visual acuity range of 0.3 to 0.8 (decimal) (20/63 to 20/25 Snellen). Compared with the monofocal IOL, the accommodative IOL resulted in a similar uncorrected distance visual acuity of 0.99 ± 0.12 (20/20 Snellen) (P > .79) and a significantly better uncorrected near visual acuity of 0.91 ± 0.11 (20/22 Snellen) (P < 2.7 × 10-6). A significant correlation of 0.51 (P < 1.3 × 10-7) was found between the objective and subjective accommodative amplitudes with the accommodative IOL. CONCLUSIONS Eyes implanted with the accommodative IOL showed similar amounts of objective and subjective accommodation. [J Refract Surg. 2018;34(2):78-83.].

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Potential of the 1 CU accommodative intraocular lens.

AIM To assess the accommodative power of a new foldable monofocal intraocular lens. METHOD A prospective randomised non-masked clinical interventional study. The study included 40 patients attending the hospital for cataract surgery and who were randomly distributed into a study group receiving a new foldable monofocal intraocular lens with flexible haptics, and a control group receiving a st...

متن کامل

Subjective and objective performance of the Lenstec KH-3500 "accommodative" intraocular lens.

AIM To determine whether eyes implanted with the Lenstec KH-3500 "accommodative" intraocular lenses (IOLs) have improved subjective and objective focusing performance compared to a standard monofocal IOLs. METHODS 28 participants were implanted monocularly with a KH-3500 "accommodative" IOL and 20 controls with a Softec1 IOL. Outcome measures of refraction, visual acuity, subjective amplitude...

متن کامل

Near Visual Performance Results of the Accommodating Intraocular Lens (Tetraflex)® in Comparison to Monofocal Foldable Intraocular Lens

Purpose: To evaluate the near visual performance of an accommodative intraocular lens (IOL); Tetraflex, in comparison to a standard monofocal foldable IOL in cataract surgery. Setting: Eye Research Center, Farabi Eye Hospital, Department of Ophthalmology, Tehran University of Medical Sciences, Iran. Methods: Forty six eyes of 23 patients with cataract underwent phacoemulsification and accommoda...

متن کامل

Optical principles, biomechanics, and initial clinical performance of a dual-optic accommodating intraocular lens (an American Ophthalmological Society thesis).

PURPOSE To design and develop an accommodating intraocular lens (IOL) for endocapsular fixation with extended accommodative range that can be adapted to current standard extracapsular phacoemulsification technique. METHODS Ray tracing analysis and lens design; finite element modeling of biomechanical properties; cadaver eye implantation; initial clinical evaluation. RESULTS Ray tracing anal...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of refractive surgery

دوره 34 2  شماره 

صفحات  -

تاریخ انتشار 2018